Shutting down

To shut down the boiler, just press the button 'P4' for about 2 seconds.
The auger is immediately stopped and the fume extractor is brought to
high speed, making the message 'FINAL CLEANING' appear on the
display.
At the end of the operation the message 'OFF' appears in the dialogue
box.
During the shutdown stage the boiler cannot be restarted until the
fume temperature has fallen below a set value for a fixed time, with the
message 'WAITING COOL' appearing in the dialogue box.
At the end of the operation, the message 'OFF' will appear in the dialog
box.

Menu

Press button 'P3' (SET) to access the menu; this is divided into various items and levels for accessing the settings of the electronic
controller.
The following table summarises the menu structure with the selections available to the user.
Menu Item
Position Level 2º
M1-1
M-1-2
Menù 01 Set Crono
M-1-3
HR EVO 290 - 350 - 390
Menu Item
EnableChrono
Day Program
Weekly Program
use and maintenance manual
Position
Parameter Name
Level 3º
M-1-1-01
Enable Chrono
M-1-2-01
Day Chrono
M-1-2-02
Start 1 Day
M-1-2-03
Stop 1 Day
M-1-2-04
Start 2 Day
M-1-2-05
Stop 2 Day
M-1-3-01
Week Chrono
M-1-3-02
Start Prog-1
M-1-3-03
Stop Prog-1
M-1-3-04
Monday Prog-1
M-1-3-05
Tuesday Prog-1
M-1-3-06
Wednesday Prog-1
M-1-3-07
Thursday Prog-1
M-1-3-08
Friday Prog-1
M-1-3-09
Saturday Prog-1
M-1-3-10
Sunday Prog-1
M-1-3-11
Start Prog-2
M-1-3-12
Stop Prog-2
M-1-3-13
Monday Prog-2
M-1-3-14
Tuesday Prog-2
M-1-3-15
Wednesday Prog-2
M-1-3-16
Thursday Prog-2
M-1-3-17
Friday Prog-2
M-1-3-18
Saturday Prog-2
M-1-3-19
Sunday Prog-2
M-1-3-20
Start Prog-3