Installation
Only use the unit in its horizontal position and ensure stable seating on a firm ground. The unit must be positioned
below the water surface level. The unit can be placed within the pond (submersed) or outside of the pond (dry). Please
note the installation examples (A and B). Do not carry or pull the unit using the connection cable. Ensure that the unit
will never run without water flowing through!
To fit the suction hose with the unit installed outside of the pond (dry), remove the two strainer cheeks by unscrewing
the screws, then remove the front plate of the strainer.
For replacement, the support foot (C) can be removed by releasing the locking lever (D) at the underside of the support
foot and pulling it to the rear. To install the support foot, push the pump body onto the foot until it engages (E).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! The unit is heavy.
Possible consequence: Lifting and carrying the unit could put considerable strain on your cardiovascular
and musculoskeletal system.
Protective measure: Only lift and carry the unit with the help of a second person.
Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).
This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
Immerse the unit in water for approx. 1 hour prior to switching it on for the first time. Following this, operate the
unit for 10 minutes against an almost closed pressure socket. Reducing cap/plug is already fitted on delivery.
Following this, you can fit the nozzle and arrange the spray pattern of your fountain system.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the