Parts Replacement/Maintenance
Chart 1 – Air Caps
ORDER NO. FOR
NUMBER
AIR CAP
ON CAP
PRO-103-HV30
HV30
(HVLP)
PRO-103-TE10
TE10
(High Efficiency)
PRO-103-TE20
TE20
(High Efficiency)
NOTE 1: Guns with HVLP caps must not exceed 0.7 bar (10 psi) air cap pressure with
gun fully triggered. (Aproximately 24 psi gun inlet pressure.) (See accessories
for air cap test kit which is available to set the exact cap pressure.)
When used with the High Efficiency caps, this gun can be used
in unregulated areas and certain approved regulated areas. See
www.autorefinishdevilbiss.com for a complete listing of approved areas and
requirements for regulatory compliance. Gun inlet pressure may be adjusted
as required to any desired value in areas not requiring EPA compliance.
NOTE 2: When removing air cap from retaining ring, don't remove slip ring (2)
or retaining ring seal (5) from retaining ring. Damage to the parts may
occur. Slip ring and retaining ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2 – Fluid Nozzles & Fluid Needles
NO. ON
TIP SIZE I.D.
FLUID NOZZLE
(MM)
PRO-200-12-K
1.2
PRO-200-13-K
1.3
PRO-200-14-K
1.4
PRO-200-15-K
1.5
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time.
Lightly lubricate the threads of the fluid nozzle before reassembling. Torque
to 18–20 Nm (13–15 ft-lbs). Don't over tighten the fluid nozzle. Use 10 mm
wrench supplied with gun.
RECOMMENDED
AIR FLOW
INLET PRESSURE
LPM/SCFM
BAR/PSI
1.4 – 1.6 bar
411 – 467 LPM
20 – 24 psi
14.5 – 16.5 SCFM
1.4 – 2.4 bar
212 – 311 LPM
20 – 35 psi
7.5 – 11.0 SCFM
1.1 – 1.8 bar
255 – 340 LPM
16 – 26 psi
9 – 12 SCFM
NO. ON
FLUID NEEDLE
PRO-301-K
PRO-301-K
PRO-301-K
PRO-301-K
TB-1020