Indicator lamp system care is illumi-
Note: Burner can operate 5 more hours.
System care tank is empty, due to tech-
–
nical reasons a remainder stays in the
tank.
Refill system care.
Indicator lamp system care is blink-
Note: Burner operation no longer possible.
System care container is empty.
–
Refill system care.
Indicator lamp detergent 1 is illumi-
Detergent tank 1 is empty.
–
Refill detergent.
Indicator lamp detergent 2 is illumi-
Detergent tank 2 is empty.
–
Refill detergent.
Appliance is not running
No power
–
Check power connection/conduit.
Device is not building up pressure
Air within the system
–
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
Pressure is set to MIN
–
Set pressure to MAX.
Sieve in the water connection is dirty
–
18
nated
ing
nated
nated
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
Amount of water supply is too low.
–
Check water supply level (refer to tech-
nical data).
Device leaks, water drips from the
bottom of the device
Pump leaky
–
Note: 3 drops/minute are allowed.
With stronger leak, have device
checked by customer service.
Device turns on and off while hand
spray gun is closed
Leak in the high pressure system
–
Check high pressure system and con-
nections for tightness.
Device is not sucking in detergent
Leave device running with open deter-
gent dosage valve and closed water
supply, until the swimmer tank is
sucked empty and the pressure falls to
"0".
Open the water supply again.
If the pump still is not sucking in any deter-
gent, it could be because of the following
reasons:
Filter in the detergent suck hose dirty
–
Clean filter.
Backflow valve stuck
–
Remove the detergent hose and loosen
the backflow valve using a blunt object.
– 11
EN