4
I. WARNINGS

1. Counter-indications

5
5
5
Important counter-indications
Cardiac stimulator (pacemaker)
7
Epilepsy
7
Pregnancy (no positioning in the
8
abdominal area)
8
Serious arterial circulatory problems
9
in the lower limbs
9
Abdominal or inguinal hernia
9
9
9
Precautions when using
10
the Compex
10
After trauma or a recent operation
10
(less than 6 months)
Muscular atrophy
11
Persistent pains
11
Need for muscular rehabilitation
12
12
Osteosynthesis equipment
13
The presence of osteosynthesis
14
equipment (metallic equipment in
15
contact with the bone: pins, screws,
16
plates, prostheses, etc.) is not a contra-
indication for the use of Compex programs.
17
The electrical current of the Compex is
specially designed to have no harmful
18
effect with regard to osteosynthesis
equipment.
18
19
19
19
n all of the above cases, you are
I
advised to:
20
never use the Compex for prolonged
21
periods without medical advice;
28
consult your doctor if you are in
31
any doubt whatsoever;
35
read this manual carefully, in
39
particular chapter VI, which provides
44
information concerning the effects
and indications of each stimulation
program.
49

2. Safety measures

What you should not do with
the Compex
Do not use the Compex in water
or in a humid atmosphere (sauna,
hydrotherapy, etc.).
Never carry out an initial stimulation
session on a person who is standing.
The first five minutes of stimulation
must always be performed on a
person who is sitting or lying down.
In rare instances, very highly strung
people may have a vagal reaction.
This is of psychological origin and is
connected with a fear of the muscle
stimulation as well as surprise at
seeing one of their muscles contract
without having intentionally contracted
it themselves. This vagal reaction
produces a feeling of weakness with
a fainting tendency, slowing down
of the heartrate and a reduction in
arterial blood pressure. If this does
occur, all that is required is to stop
the stimulation and lie down with the
legs raised for the time it takes for
the feeling of weakness to disappear
(5 to 10 minutes).
Never allow movement resulting
from muscular contraction during a
stimulation session. You should
always stimulate isometrically; this
means that the extremities of the limb
in which a muscle is being stimulated
must be firmly fixed, so as to prevent
the movement that results from
contraction.
Do not use the device at less than
1.5 metres from a short-wave device,
a micro-wave device or high
frequency (H.F.) surgical equipment
to avoid the risk of causing skin
irritations or burns under the electrodes.