Mounting Dimensions; Installation; Hook-Up Diagrams - DART Controls 65E CONTROL Serie Manual De Instrucciones

Ocultar thumbs Ver también para 65E CONTROL Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.70"
SIDE VIEW
SIDE VIEW
SIDE VIEW
Caution: Do not mount controller where ambient temperature is outside the range of -10° C (15° F) to 45° (115° F).
Before attempting to wire the control, make sure all power is disconnected. Recheck code designation to assure proper voltage
is present for the control. Caution should be used in selecting proper size of hook-up wire for current and voltage drop. Note: the
battery and armature wire size on 65E models must be a minimum of 12 gauge.
DO NOT REVERSE POSITIVE AND NEGATIVE BATTERY LEADS. THIS WILL DAMAGE THE CONTROL.
TO CHANGE MOTOR DIRECTION, INTERCHANGE THE POSITIVE AND NEGATIVE ARMATURE LEADS.
Refer to the wiring diagrams below for proper connection of DC Voltage, Armature, and Speedpot wiring to the control.
CAUTION !!
TURN POWER OFF WHILE MAKING CONNECTIONS .
To properly adjust the CURRENT LIMIT setting, a DC ammeter should be placed in series with the armature line. This meter can
be removed after the control is adjusted.

MOUNTING DIMENSIONS

65E20 & 65E40 MOUNTING
3.62"
.188 DIA.
(4 SLOTS)
1.75"
65E60 MOUNTING

INSTALLATION

HOOK-UP DIAGRAMS

WARNING:
2
7.00"
6.50"
TOP VIEW
9.00"
7.50"
7/32" DIA.
(4 SLOTS)
NOTE:
When mounting the control, allow clearance above
components to prevent shorting
TOP VIEW
TOP VIEW
.344"
SLOT DEPTH
.75"
(continued)

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido