WIRING CONNECTION
10
Connecting cables between indoor unit and outdoor unit
Outdoor
unit
3
2
1
!
CAUTION
The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4
S4 (This equipment shall be provided with a cord set complying with the national regulation.
10±3 mm
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cord set complying with the national
regulation.)
10±3 mm
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
If the supply cord is damaged, it must be replaced by a special cord or assembly availible
from the manufacturer of its service agent.
Indoor
unit
3
2
1
ATUQ22GPLA4
ABUQ22GM1A4
ATUQ30GPLA4
ABUQ30GM1A4
AUUQ40GH4
AUUQ50GH4
AUUQ60GH4
When the connection line between the indoor unit and out-
dooor unit is over 40 m, connect the telecommunication line
and power line separately.
ATUQ22GPLA4
ABUQ22GM1A4
2
ATUQ30GPLA4
ABUQ30GM1A4
AUUQ40GH4
AUUQ50GH4
AUUQ60GH4
Model
1
0.75
Phase(Ø) Area(mm
2
)
1
2.5
1
4.0
1
6.0