pro.Bose.com
Description
Available Controls
Description
Available Controls
LOCAL INPUTS displays the following information for analog input channels 1 - 12:
• Audio level (-60 dBu to +24 dBu)
• PH POWER: Open circle indicates that there is no phantom power applied to the corresponding
input channel. Closed circle indicates that there is phantom power applied to the corresponding
input channel. Apply or remove phantom power for each channel using ControlSpace Designer
software.
• MUTE: Open circle indicates that the corresponding input channel is not muted. Closed circle
indicates that the corresponding input channel is muted. Set the mute status for each channel
using ControlSpace Designer software.
LOCAL OUTPUTS displays the following information for analog output channels 1 - 8:
• Audio level (-60 dBu to +24 dBu)
• POLARITY: Positive polarity is indicated by a "+" symbol. Negative polarity is indicated by a "-"
symbol. Set the polarity for each channel using ControlSpace Designer software.
• MUTE: Open circle indicates that the corresponding output channel is not muted. Closed circle
indicates that the corresponding output channel is muted. Set the mute status for each channel
using ControlSpace Designer software.
Input channels 1 - 12 appear on the first screen. Turn the knob clockwise to view output channels 1 -
8. To return to the MAIN MENU, turn the knob counter-clockwise.
AmpLink displays audio levels (-60 dBu to +24 dBu) for AmpLink output channels 1 - 8.
To return to the MAIN MENU, turn the knob counter-clockwise.
LOCAL IN/OUT
AmpLink