REGULACIONES

Antes de cada ajuste desconectar el aparato de la
alimentación eléctrica.
Terminados los ajustes o preajustes, los posibles sellados
deben ser restablecidos por el técnico.
Nuestros quemadores no necesitan ninguna regulación de
aire primario.
9) GRIFOS
Regulación de "Mínimo":
-Switch on the burner and turn the relative knob to the "Reduced
rate" position (small flame fig. 1).
- Remove knob "M" (fig. 12 and 12/A) of the tap, which is simply
pressed on to its rod. The by-pass for minimal rate regulation
can be: beside the tap (fig. 12) or inside the shaft. In any case, to
access to regulation, it can be done trought the insertion of a
small screwdriver ''D'' beside the tap (fig. 12) or in the hole ''C''
inside the shaft of the tap (fig 12/A). Turn the throttle screw to the
right or left until the burner flame has been adequately regulated
to the "Reduced rate" position.
The flame should not be too low: the lowest small flame should
be continuous and steady. Re-assemble the several
components.
Queda claro que el ajuste mencionado debe ser realizado
sólo por quemadores que funcionan con G20, mientras que
con quemadores que funcionan con G30 o G31 el tornillo
debe estar fijado a fondo (girando en sentido antihorario).
FIG. 12/A
FIG. 12
18