Extensions; Maintenance And Repairs - Blastrac BDC-22 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating manual BDC-22

Extensions

If an extension cable is used, make sure it is suitable
for the power input and protection degree of the
vacuum cleaner.
Minimum section of extension cables: 2.5 mm
Maximum length = 20 m
Cable (EU) = H07 RN - F
Cable (US) = SJT
WARNING!
Sockets, plugs, connectors and installation
of the extension cable must maintain the IP
protection degree of the vacuum cleaner, as
indicated on the data plate.
WARNING!
Never spray water on the vacuum cleaner:
this could be dangerous for persons and could
short circuit the power supply.
WARNING!
The vacuum cleaner's power socket must be
protected by a differential circuit-breaker
with surge current limitation, that shuts
off the power supply when the current
discharged to the ground exceeds 30 mA for
30 msec. or an equivalent protection circuit.

Maintenance and repairs

Disconnect the vacuum cleaner
from its power source before
2
cleaning, servicing, replacing
parts or converting it to another
version/variant, the plug must be
disconnected from the socket.
Carry out only the maintenance
operations described in this manual.
Use only original spare parts.
Do not modify the vacuum cleaner in any
way.
Failure to comply with these instructions
could jeopardize your safety. Moreover,
such action would immediately make the EC
declaration of conformity issued with the
vacuum cleaner void.
For maintenance procedures not described
in this manual, please contact the
manufacturer's technical support or sales
network.
www.blastrac.com ‒ custserv@blastrac.com
7/17
WARNING!
WARNING!
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido