Primary Filter Shaker; Emergency Stopping; Replacement Of Dust Bags - Blastrac BDC-22 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating manual BDC-22

Primary filter shaker

According to the quantity of vacuumed material, if the
vacuum gauge pointer (2, Fig. 7) goes from the green
zone (3, Fig. 7) to the red zone (1, Fig. 7), shake
the primary filter by turning the lever (4, Fig. 5)
clockwise/counterclockwise for at least 5 complete
cycles.
WARNING!
Stop the vacuum cleaner before using the
filter shaker.
Do not shake the filter while the vacuum
cleaner is on, as this could damage the filter.
Wait before restarting the vacuum cleaner, to allow
the dust to settle. Replace the filter element if the
vacuum gauge pointer stays in the red zone (1,
Fig. 7) even after the filter has been shaken (see
"Primary filter replacement").

Emergency stopping

Turn the buttons (1 and 2 Fig. 5) to "0". The vacuum
cleaner stops.
WARNING!
The motors and internal components of
the vacuum cleaner will still be electrically
powered.
To start the vacuum cleaner again, turn the buttons of
each single motor (1 and 2, Fig. 5) to "I".

Replacement of dust bags

WARNING!
Before proceeding with these
operations, turn off the vacuum
cleaner and remove the plug from
the power socket.
WARNING!
These operations can only be carried
out by trained and qualified personnel
who must wear adequate clothing, in
compliance with the laws in force.
Take care not to raise dust when this
operation is carried out. Wear a P3
protective mask.
In case of hazardous and/or harmful dust,
use only the bags recommended by the
manufacturer (see "Recommended spare
parts").
The bag must only be disposed of by
qualified personnel and in compliance
with the laws in force.
WARNING!
Installing a bag not suitable for the class of
dust to be vacuumed, or incorrect installation,
can create a health risk for people exposed.
How to replace Longopac
hazardous dust
Turn the bag full of dust (1, Fig.8) on itself to
obtain a section of coiled bag to be tightened with
two clamps (2, Fig.8).
Place the two clamps at a distance of 50 mm
between them, then with a pair of scissors cut
between the two clamps.
Remove the bag full of dust (1, Fig.8) and place
the new section of Longopac
www.blastrac.com ‒ custserv@blastrac.com
11/17
bags for
®
Figure 8
(3, Fig.8).
®