S TEP 1 : ConnECTInG AnD FITTInG ThE BELT .
1  
Check your SPORT-ELEC® unit is stopped.
f
f
Open out the belt. Fix the electrodes to the inside of the belt using the snap fasteners.
f
f
Place the belt (or 2 half-belts) onto the zone(s) to be stimulated (stomach, back, arms, thighs, calf ), and adjust them using "scratch"
f
f
strips to ensure the electrodes are properly in contact with the skin. If required, use the belt extension
Take the connectors of your device and connect them to the belt connectors per groups of two (photo F page 2).
f
f
Move the belt slightly left or right (with device powered off ) to feel the contractions on the abdominal area.
f
f
If an electrode hurts or if you feel any tingling, stop the device.
f
f
S TEP 2 : STARTInG ThE BELT FunCTIon
2  
Once your unit is connected, install yourself comfortably and start your unit using the procedure "Starting the unit" detailed
previously in paragraph II.
S TEP 3 : SToPPInG ThE BELT FunCTIon
3  
Once the program is finished, disconnect the device from the belt.
Remove the excess cream on the built-in electrodes using a wipe dampened with water, then dry them.
Iv. RECoMMEnDATIon FoR uSE
P RECAuTIonS
1  
Some persons may experience skin irritation or hypersensitivity due to the electrical stimulation or contact cream.
f
f
Keep away from children or people with mental disabilities. The device contains small pieces that can be swallowed.
f
f
Use this device only with the leads, electrodes, and accessories recommended by the manufacturer.
f
f
Do not use portable electrical stimulators while driving, operating machinery, or during any activity in which electrical stimulation
f
f
can put the user at risk of injury.
Use with caution in the following circumstances :
persons with suspected or diagnosed epilepsy
f
f
when there is a tendency to bleed internally following an injury of fracture
f
f
following recent surgical procedures when stimulation may disrupt the healing process
f
f
over areas of skin that lack normal sensation
f
f
GET YouR DoCToR'S ADvICE IF :
You have back troubles. You should also ensure the intensity
f
is kept low.
You have any serious illness or injury not mentioned in
f
this guide.
You have recently undergone a surgical procedure.
f
You take insulin for diabetes.
f
TIPS ExPLAnATIonS FoR SMALL SIZES :
If the belt overlaps with electrodes on the body, fold the
f
overlapping part of the belt by means of scratch sections.
12
- USER MANUAL
ConTACT SPoRT-ELEC® InSTITuT
oR An AuThoRIZED PRovIDER IF :
You experience any irritation, skin reaction, hypersensitivity
f
or other adverse reaction. However, please note that some
reddening of the skin is quite normal under the belt during
and for a short time after exercise.
An effective treatment should not cause undue discomfort.
f
SPORT-ELEC® INSTITUT will not accept responsibility if the
guidelines and instructions supplied with this unit are not
followed.
If you are in any doubt about using the device for any
f
reason, please consult your doctor before use.
RECoMMEnDATIonS oF uSE
You can restart a program's cycle on another muscle zone.
f
For optimum use, refer to the diagrams shown in this
f
manual.
Clean the unit and its cables with a cloth dampened with a
f
disinfecting solution diluted in water at 1/10th.
If the device is not likely to be used for some time, the
f
batteries should be removed.
TRouBLE ShooTInG
If your device doesn't work properly, do not use it and
f
contact your retailer.
2  
W ARnInGS
The long-term effects of electrical stimulation are unknown.
Wait before using your BODY CONTROL SYSTEM:
When applying the belt, always remember to place the belt only on the abdomen and as indicated in this manual.
f
f
Do not apply stimulation on the neck. Severe spasm of the muscles may occur and the contractions may be strong enough to
f
f
close the airway or cause difficulty in breathing.
Stimulation over the neck could also have adverse effects on the heart rhythm or blood pressure.
f
f
Do not apply stimulation across the chest because the introduction of electrical current into the chest may cause rhythm distur-
f
f
bances to the heart, which could be lethal.
The effects of stimulation on the brain are unknown. Therefore, do not apply stimulation across the head and do not place
f
f
electrodes on the opposite side of the head.
Apply stimulation only to normal, intact, clean skin. Do not apply stimulation over open wounds or over swollen, infected, or
f
f
inflamed areas or skin eruptions, e.g. phlebitis, thrombophlebitis, varicose veins, etc.
Do not apply stimulation in the bath or under the shower.
f
f
Do not use this device while sleeping.
f
f
If you have an IUD contraceptive device, do not practice electro-stimulation.
f
f
The safety of use of this device when used with an IUD has not been established
WARnInG :
• Use only on those parts of the body for which the accesso-
ries were designed.
• Functions only on batteries
• Not to connect to another source of power
ADvERSE REACTIonS
Skin irritation and burns beneath the electrodes have been
reported with the use of electrical stimulators applied to
the skin.
RECoMMEnDATIonS
Please apply regulations enforced in your country
when disposing your product at its end of life.
Therefore, please discard it in a location planned to
this effect, ensuring it is disposed in an environment-
friendly manner.
- USER MANUAL
RESTRICTIonS oF uSE
To benefit fully of your electrostimulation session, please pay
attention to the following guidelines :
The belt must not be connected to other objects.
f
Do not touch inside the belt while the BODY CONTROL
f
SYSTEM is switched on.
Do not use while driving or operating machinery.
f
Do not use in wet environment.
f
Use this device in a clean place (without dust nor dirt..).
f
Keep your unit at distance from heat source.
f
Keep your unit at distance from short-wave emitting equip-
f
ment or high frequency surgical devices.
To reposition the belt during a session :
f
Always stop the program currently running, unfasten
the belt and refasten it after the belt's position has been
adjusted.
After strenuous exercise or exertion :
f
Always use a lower intensity to avoid muscle fatigue.
CLEAnInG & MAInTEnAnCE ConDITIonS
No washing
f
No solvent
f
No drying
f
No ironing
f
No laundering
f
Clean accessories with a humid sponge soaked with deter-
f
gent and wipe with a cloth.
Clean the unit with a cloth soaked in with disinfectant
f
(Mercryl type) diluted with water at 1/10th.
Rehydrate the adhesive side of the electrodes before and
f
after use. A disinfectant agent can be used. They should
be stored on the original backing sheet in a plastic bag
between 5°C and 10°C (for example in a separate compart-
ment in your refrigerator).