Installation Instructions
ControlKeeper® 4A
General Information
The ControlKeeper 4A model is shipped in one package
and is configured with a dual tapped 120V/277V/347V
60 Hz or 230V/240V 50 Hz transformer. It can be
configured with different relay types as needed to achieve
lighting needs. Please refer to your order information to
determine which model you have purchased.
The ControlKeeper 4A can control up to four relays per
panel with optional support for up to four 0-10V dimming
control outputs to allow for combinations of relay
switching and load dimming.
Getting Started
1.
Do not discard these installation instructions. Please
keep for future reference and operation information.
2.
Always disconnect all power before wiring.
3.
Use only as intended and at the listed voltage.
4.
All installation and service must be performed by
qualified personnel or service technicians.
5.
Install in accordance with the National Electrical Code
and any other codes which may apply.
6.
Installation and wiring information contained in this
document is based on industry-accepted standards
and practices. If conflicts exist between these
instructions and any applicable codes or ordinances,
please contact Greengate before proceeding with the
installation.
7 .
High voltage is present inside the enclosure. Use
extreme caution when performing maintenance on
this equipment. Failure to follow this warning and
proper safety procedures could result in severe injury
or death, and/or damage to the equipment.
8.
Document all wiring and device terminations and
locations so that devices can be properly configured
and programmed for operation.
Model# CK4A-SSRC
Model# CK4A-SLRC
Model# CK4A-STPRC
Mounting the Cabinet
1.
Choose a dry location on a firm surface convenient to
the circuits being controlled. Allow full clearance for
the door of the enclosure to open fully.
2.
Mount the ControlKeeper 4A cabinet using the holes
provided in the back of the enclosure.
3.
All line voltage conductors must enter the cabinet on
the right side of the enclosure.
4.
All low voltage conductors must enter the cabinet on
the left side of the enclosure.
5.
Remove all debris and metal shavings from
the enclosure before applying power to the
ControlKeeper 4A.
N
ote:
Make certain that high voltage and low voltage
wiring enters the enclosure separately. Failure to
separate high voltage from low-voltage wiring may
cause interference with functionality. High Voltage
wiring should not be brought into the enclosure
through the left side of the enclosure.
Low voltage wiring can be brought into the enclosure
from the bottom left or upper left of the enclosure. Due
to limited space on the left side of the enclosure, it is
recommended that connections be brought through the
top or bottom of the enclosure for the low-voltage wiring.
Bring Low Voltage in
through the Left Side of
the Enclosure
Figure 1: ControlKeeper-4 Enclosure
INS #
Bring High Voltage in
through the Right Side
of the Enclosure
50-022510-02
LED1
ADDRESS
54-022510-
NETWORK
ALL OFF
LED2
ALL ON
LED3
1
3
2
4
5
6
7
8
J1
Reset
SW1
SW1
SW2
SW3
CAN-RX
CAN-TX
H1
LED4
LED5
J2
U1
U2
J3
U5
U6
L1 L2 L3 L4
J4
U7
J5
TB1
C20
PS1
U8
LED6
RSC STAT
SR1
U9
L1
J6
PCI-NET TERM
S1
U10
U11
RESET PICS
SC1
C29
REG1
REG2
REG3
U12
LED7
SWIN STAT
SR2
POWER
U15
U16
C48
U13
U14
U17
U18
L2
C40
C47
BR1
U19
U20
ANALOG INPUTS
TB3
TB4
DIMMING OUTPUTS
TB5
SWITCH INPUTS
TB6
TB2
LSO TEST
TB7
C49
LOCAL
J7
J8
AN AN AN AN
IN
IN
LS
IN
IN
LS
IN
IN
LS
IN
IN
LS
1
2
3
4
ANALOG COM
VIO
1
GRY
1
VIO
2
2
GRY
3
VIO
3
GRY
VIO
4
GRY
4
1
+24
2
1
3
+24
4
2
5
+24
6
3
7
+24
8
4
+24 GND
C39
REMOTE
TP1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Eaton Greengate ControlKeeper 4A CK4A-SSRC

  • Página 1 Model# CK4A-SSRC Model# CK4A-SLRC INS # Installation Instructions Model# CK4A-STPRC ControlKeeper® 4A General Information Mounting the Cabinet Choose a dry location on a firm surface convenient to the circuits being controlled. Allow full clearance for The ControlKeeper 4A model is shipped in one package the door of the enclosure to open fully.
  • Página 2: General Information

    General Information Power Supply Wiring Standard Relay Card Wiring The ControlKeeper 4A contains a multi-tapped transformer The standard relay is a simple contact closure, breaking the that is available in 120V/277V/347V 60 Hz or 230V/240V 50 line and load wires of a normal circuit. To wire the relay into Hz models.
  • Página 3 Network Wiring Notes Relay Wiring Relay Wiring Wire: 8 AWG Max. Wire:8 AWG Max. Relay Rating: 20 amps, 120/277/347V Relay Rating: 20 amps, 208/240/480V To Circuit Breaker#1 To Circuit Breaker To Lighting Load To Lighting Load To Circuit Breaker#2 To Lighting Load Figure 3: Latching Relay Card Wiring Two Pole Relay Card Notes Figure 4: Two Pole Relay Card Wiring...
  • Página 4 Network Wiring Detail Leave all shields disconnected making certain that End Panel shield is not exposed. These wire types will be Network connected to a special terminal block on the right side LED1 ADDRESS 54-022510- 50-022510-02 NETWORK ALL OFF LED2 ALL ON LED3 Reset...
  • Página 5 Dimmer Wiring Information Switch Position Value Figure 7: Address To Dimming To Dimming ote: All panels must be assigned a unique Network Ballast Ballast Address in order to communicate over the lighting Grey (-) Wire Violet (+) Wire network. Switch positions are labeled 1 through 8 and are valued at 1 through 128 as shown above.
  • Página 6 Lighted Switch Notes Local Remote Local Remote Jumper in Local ON/IN Jumper in Pilot Lit Position +24VDC Momentary Local Position OFF/IN PILOT/LS Switch (4 Wire) ON/IN Momentary +24VDC Switch (3 Wire) OFF/IN Figure 9: ControlKeeper 4A Analog Input Wiring ON/IN Toggle Switch +24VDC (2 Wire)
  • Página 7 Moved to Local Position communications problems occur that require troubleshooting (Jumper Over Top Pins) assistance, additional charges for support may be assessed. GDS-I Cabling is EAton’s Cooper LC Cable, Belden 1502R, or Belden 1502P ControlKeeper® 4A Figure 12: Digital Switch Gateway Wiring Detail...
  • Página 8: Applying Power

    Digital Switch Wiring Applying Power ALL OFF/AUTO/ALL ON Switch Notes After wiring is complete, make certain to clean panel In addition to the individual relay override switch, there of all wire clippings and fragments ensuring that no is a hardware override switch that allows the override of fragments get lodged between the circuit board and all relays on the board.
  • Página 9 Digital Switch Wiring Digital Switch LEDs: Status LED is not flashing. The Soft Reset Command will not cause loss of panel programming. To perform a Soft These LEDs, labeled CAN-TX and CAN-RX, will flash when Reset Command, press in and then immediately release Digital Switch information is being passed back and forth the reset button.
  • Página 10: Repair Information

    Digital Switch Wiring Repair Information Operation Notes If a repair becomes necessary on your ControlKeeper 4A The ControlKeeper 4A consists of a logic board, transformer unit, please refer all service to Greengate’s technical support and relay card. There are several features of note as pointed line at 1-800-553-3879.
  • Página 11: Renseignements Généraux

    Renseignements généraux Renseignements généraux Dégagez tous les débris et les rognures de métal du boîtier avant de mettre le ControlKeeper 4A sous tension. Le modèle ControlKeeper 4A est expédié dans un seul colis. Il est équipé d’un transformateur à deux gradins de emarque: Assurez-vous que les câblages de haute tension 120-277V/347V en 60 Hz ou de 230V/240V en 50 Hz.
  • Página 12 Renseignements généraux Branchez le fil noir uni au circuit de dérivation qui Branchez un disjoncteur de dérivation hors tension alimente le transformateur. de 120 ou 277 volts, 20 A maximum à l’emplacement étiqueté LINE du bornier du relais. Branchez le câble de charge à l’emplacement étiqueté Tableau de couleurs du transformateur LOAD du bornier de sortie.
  • Página 13 Renseignements généraux Branchez le câble de charge à l’emplacement étiqueté Câblage du relais LOAD du bornier de sortie. Fil:8 AWG Max. Classification du relais: 20 A, 208/240/480V Câble du relais Fil: 8 AWG max. Vers le disjoncteur 1 Classification du relais: 20 A, 120/277/347 V Vers la charge Vers le d’éclairage...
  • Página 14 Renseignements généraux Détail du câblage des panneaux d'extrémité du ADDRESS 50-022510-02 NETWORK LED1 ALL OFF LED2 ALL ON LED3 54-022510- réseau Reset CAN-RX CAN-TX LED4 LED5 LED6 RSC STAT PCI-NET TERM RESET PICS REG1 REG2 REG3 LED7 SWIN STAT POWER ANALOG INPUTS DIMMING OUTPUTS SWITCH INPUTS...
  • Página 15 Renseignements généraux Position de l'interrupteur Valeur Figure 7: Adresse Fil violet (+) Fil gris (-) Pour communiquer dans le réseau d’éclairage, ote: vers le ballast vers le ballast tous les panneaux doivent posséder une adresse de gradation de gradation de réseau unique. Comme illustré ci-dessus, les commutateurs sont associés à...
  • Página 16 Renseignements généraux Bretelle de Bretelle de commande ON/IN Interrupteur commande locale en +24 V c.c. de rappel pour locale en OFF/IN position voyant (4 fils) VOYANT/LS position locale locale ON/IN Interrupteur de +24 V c.c. rappel (3 fils) OFF/IN Figure 9: Câblage pour entrée analogique au ON/IN Interrupteur à...
  • Página 17 Greengate avec le système de commande Les interrupteurs numériques nécessitent des câbles de d’éclairage. Le ControlKeeper 4A est capable d’alimenter type Eaton’s Cooper LC, Belden 1502R (non-plenum),ou plusieurs de ces dispositifs. Consultez le tableau ci-dessous Belden 1502P (plenum).
  • Página 18 Renseignements généraux 50-022510-02 ADDRESS LED1 LED2 LED3 54-022510- NETWORK ALL OFF ALL ON Reset Interrupteur ALL Interrupteur prioritaire CAN-RX CAN-TX LED5 OFF , AUTO, ALL ON LED4 du relais individuel L1 L2 L3 L4 LED6 RSC STAT PCI-NET TERM RESET PICS LED7 REG1 REG2...
  • Página 19 Renseignements généraux DEL d’état de relais individuel: Il existe quatre DEL d’état DEL d'état du de relais, une pour chacun des relais du ControlKeeper 4A. DEL du voyant de microprocesseur l'interrupteur prioritaire Consultez la Figure 14 pour connaitre l’emplacement de ces DEL du voyant de DEL d'état de DEL de statut.
  • Página 20 Renseignements généraux Programmation du ControlKeeper 4A Commutateur de réinitialisation des communications: Dans certains, cas, il est préférable de réinitialiser Le ControlKeeper 4A se programme à l’aide du logiciel uniquement l’entrée et les puces de communication du Keeper Enterprise. Pour en savoir davantage à ce sujet, relais.
  • Página 21 Renseignements générau Renseignements générau Figure 16: Schéma des pièces DEL du réseau 15. Connexion d’alimentation secondaire du transformateur DEL ALL ON 16. Bretelles de commande locales Interrupteur prioritaire matériel du panneau 17 . Borne d’alimentation de périphérique: + 24 V c.c., CC (ALL OFF , AUTO, ALL ON) terre DEL ALL OFF...
  • Página 22: Información General

    Información general Información general Quite todo tipo de residuos y virutas metálicas del alojamiento antes de encender el ControlKeeper 4A. El modelo ControlKeeper 4A viene en un solo paquete y ota: Asegúrese de que los cables de alto y bajo voltaje con un transformador de doble derivación de 120V, 277V, ingresen al alojamiento por separado.
  • Página 23: Tabla De Colores Del Transformador

    Información general Tabla de colores del transformador Conecte un disyuntor de circuito de rama desenergizado de 120 o 277 voltios y 20 amperios como máximo a la posición del bloque de terminales Tensión en línea Negro del relé etiquetada como LINE (línea). 120 VCA Blanco/negro Conecte los cables de carga a la posición del bloque de...
  • Página 24: Cableado De La Tarjeta De Relé De Dos Polos

    Información general Cable del relé: 8 AWG como máximo Cableado del relé: 8 AWG como máximo Características nominales del relé: 20 amperios, Características nominales del relé: 20 amperios, 208/240/480V 120/277/347 V Hacia al disyuntor N.°1 Hacia el disyuntor Hacia la carga de Hacia la carga de iluminación iluminación...
  • Página 25: Detalles Del Cableado De La Red

    Información general Detalle del cableado de la red del panel de extremo LED1 ADDRESS 54-022510- 50-022510-02 NETWORK ALL OFF LED2 ALL ON LED3 Reset CAN-RX CAN-TX LED4 LED5 LED6 RSC STAT PCI-NET TERM RESET PICS REG1 REG2 REG3 LED7 SWIN STAT POWER ANALOG INPUTS DIMMING OUTPUTS...
  • Página 26 Información general Posición del interruptor ENCENDIDO APAGADO Valor 32 64 128 Figura 7: Dirección Hacia el balasto Hacia el balasto Todos los paneles deben tener asignada una ota: del regulador del regulador Cable violeta (+) Cable gris (-) dirección única a los fines de comunicarse en toda la red de iluminación.
  • Página 27: Cableado Del Interruptor De La Entrada De Contacto

    Información general Puente Puente remoto Interruptor ON/IN remoto local en +24 VCC momentáneo local en posición OFF/IN posición de luz piloto PILOTO/LS local local (cuatro cables) ON/IN Interruptor +24 VCC momentáneo OFF/IN (3 cables) ON/IN Interruptor conmutable Figura 9: Cableado de la entrada analógica del +24 VCC (2 cables) ControlKeeper 4A...
  • Página 28: Cableado Del Interruptor Digital

    Información general Notas sobre el fotosensor de la entrada de contacto y El tipo de cable del interruptor digital debe ser cable LC de Cooper, Belden 1502R (no impelente) o Belden 1502P sobre el sensor Greengate (impelente). Es posible utilizar un fotosensor de la entrada de contacto y sensores de movimiento Greengate junto con el sistema de Para un mejor funcionamiento de la red, se debería utilizar control de iluminación.
  • Página 29: Aplicación De La Alimentación

    Información general Interruptor TODOS APAGADOS, AUTOMÁTICO, Interruptor de anulación TODOS ENCENDIDOS individual de relés 50-022510-02 ADDRESS LED1 LED2 LED3 54-022510- NETWORK ALL OFF ALL ON Reset CAN-RX CAN-TX LED4 LED5 L1 L2 L3 L4 LED6 RSC STAT PCI-NET TERM RESET PICS REG1 REG2 REG3...
  • Página 30 Información general LED de estado del relé individual: aquí están los LED de estado de los cuatro relés, uno por cada uno de los relés en el ControlKeeper 4A. Consulte la Figura 14 para ver la LED de estado del LED del indicador del ubicación de estos LED.
  • Página 31: Información De Reparación

    Información general Programación del ControlKeeper 4A Control de configuración de eliminación: Este comando se utiliza para eliminar toda la programación de una unidad El ControlKeeper-4A se programa usando el software ControlKeeper 4A. Debería llevarse a cabo antes de Keeper Enterprise. Remítase al manual del software Keeper descargar la programación en la unidad por primera vez o Enterprise para ver los detalles de programación.
  • Página 32 Información general Notas de operación EL ControlKeeper 4A está compuesto de una placa lógica, un transformador y una tarjeta de relé. Existen varias características destacables, tal como se indica en el diagrama de referencia de elementos en la página siguiente. Figura 16: Referencia de elementos LED de la red 15.
  • Página 34 United States All trademarks are property Eaton.com of their respective owners. Eaton’s Cooper Controls Business Eaton est une marque de commerce 203 Cooper Circle déposée. Toutes les autres marques Peachtree City, GA 30269 de commerce sont la propriété de leur CooperControl.com...

Tabla de contenido