PROGRAMMING THE OPERATING LOGICS
MONOSTABLE operating logic
• Power the DEV-R2 module
• Hold the SW1 button pressed: the L1 LED lights up
• After 5 seconds the L1 LED goes off: release the SW1 button
• After 2 seconds the L2 LED lights up
• Press the SW1 button: the L2 LED goes off, indicating the
procedure is over
BISTABLE operating logic
• Power the DEV-R2 module
• Hold the SW1 button pressed: the L1 LED lights up
• After 5 seconds the L1 LED goes off: release the SW1 button
• After 2 seconds the L2 LED lights up
• After 2 further seconds the L1 LED lights up
• Press the SW1 button right away: the L1 and L2 LEDs go off,
indicating the procedure is over
TIMER operating logic
• Power the DEV-R2 module
• Hold the SW1 button pressed: the L1 LED lights up
• After 5 seconds the L1 LED goes off: release the SW1 button
• After 2 seconds the L2 LED lights up
• After 2 further seconds the L1 LED lights up
• After a few seconds the 2 LEDs go off and L1 starts blinking:
the number of blinks corresponds to a time you can set as
shown in the table:
N° Flashing
Time
1
01 sec.
2
02 sec.
3
03 sec.
4
04 sec.
5
05 sec.
6
06 sec.
7
07 sec.
8
08 sec.
9
09 sec.
10
10 sec.
11
11 sec.
12
12 sec.
13
13 sec.
14
14 sec.
15
15 sec.
• Count the number of L1 LED blinks corresponding to the time
you wish to set
• Press the SW1 button during the desired blink: the L1 LED goes
off, indicating the procedure is over
N° Flashing
Time
16
30 sec.
17
1 min.
18
1,5 min.
19
2 min.
20
2,5 min.
21
3 min.
22
3,5 min.
23
4 min.
24
4,5 min.
25
5 min.
26
10 min.
27
15 min.
28
30 min.
29
45 min.
30
60 min.
STORING THE TRANSMITTERS THROUGH THE
SW1 BUTTON (FIG.3)
L1 - the LED lights up when the SW1 button is pressed to store
or delete any transmitters
L2 - the LED lights up when the DEV-R2 module receives a code
existing in memory
Storage through L1 LED
1. Press the SW1 button of the DEV-R2 module to be
programmed: the L1 LED lights up
2. Press the button of the transmitter to be stored within 8
seconds
3. The L1 LED restarts: the code has been stored and the receiver
waits for a new code to be stored for 8 seconds
4. Memorise all the transmitters necessary
5. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
Storage through L2 LED
1. Press the SW1 button of the DEV-R2 module to be
programmed: the L1 LED lights up
2. Press the SW1 button again: L1 LED turns off and L2 LED turns
on
3. Press the button of the transmitter to be stored within 8
seconds
4. The L2 LED restarts: the code has been stored and the receiver
waits for a new code to be stored for 8 seconds
5. Memorise all the transmitters necessary
6. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
TRANSMITTER STORAGE VIA RADIO
This procedure allows for storage of transmitters without directly
accessing the module.
NOTE: it is necessary to use a remote control previously stored
(TX1) and proceed as follows:
1. Press and hold the P1+P2 buttons on TX1 transmitter for
around 5 seconds
2. Release the button: press the button on the TX2 transmitter to
be stored within 8 seconds
3. Repeat this operation for any other transmitters
4. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
MEMORY CLEARING
This procedure enables to clear all the transmitters stored in the
DEV-R2 module.
1. Switch off the DEV-R2 module
2. Hold the button SW1 and at the same time switch on the
DEV-R2 module
3. After 2 seconds, release the button SW1: the motor confirms
successful clearing by moving in both directions for half a
second
- 6 -