The generator sets to be stored for over 30 days must undergo special operations to
ensure their correct storage
1-
To protect the motor, we recommend the use of Briggs & Stratton petrol additive,
Reference No. 5041(see figure I), available for all approved distributors. Add the
additive in the fuel tank or in a storage tank. Run the motor for a few moments to
circulate the additive in the carburettor. The motor and the fuel can then be stored
for not more than 24 months
2-
While the motor is still hot, drain the oil from the casing. Replace it with new oil
of a suitable grade
3-
Remove the spark plug and pour approximately 15 ml of motor oil into the cylin-
der. Reassemble the spark plug and run the motor to distribute the oil
4-
Remove dirt from the cylinders, cylinder head blades, cooling casing, wheel
.
grille and silencer
5-
Clean the generator set
6-
Seal the AC generator air inlet and outlets with plastic adhesive tape.
7-
Store the generator set in a clean and dry place
118030-Manual-C.indd 32
.
.
.
.
.
.
EN