Assign a unique IP address to the AXIS product using a computer on your network as follows:
1.
Acquire an unused IP address for the AXIS 292 from the network administrator. The
AXIS 292 must be installed on the same subnet as the computer.
2.
Connect a standard network cable from the AXIS 292 to the network.
3.
Locate the serial number/MAC Address (S/N) on the label on the underside of the
AXIS 292.
Syntax:
arp -s <IP Address> <MAC Address> temp
ping -s 408 <IP address>
Example:
arp -s 192.168.0.125 00:40:8c:18:10:00 temp
ping -s 408 192.168.0.125
4.
Connect power to the AXIS 292.
5.
Close the ARP Ping session once 'Reply from 192.168.0.125: ...' (or similar) is displayed
(approximately 10-15 seconds).
Start a Web browser, enter the IP address in the Address/Location field and Press Enter.
6.
7.
Enter the password for the root user (administrator). See Setting the password, on page 6.
8.
The installation is now complete. Proceed to Accessing the AXIS 292, on page 10.
Notes:
• In some Unix systems, the arp command can be located in a directory that is not on the
command path.
• The default user name is root and the default password is pass. The password should be
changed to prevent unauthorized tampering. If the password is lost, the AXIS 292 must
be reset to the default settings. Refer to Factory default settings, on page 11, for instruc-
tions.