PARAMETER
VALUE
t.rSE
0.0" - 5.0"
P.SEr
0 - 1 00
t.PrE
0.5" - 1'00
no
t.P.Ch
0.5" - 1 '00
no
P.AP
30 - 100
P.Ch
30 - 100
Pr.AP
0 - 70
Pr.Ch
0 - 70
DESCRIPTION
Holding magnet delay time
This menu allows regulating the delay with which the holding magnet
jams after the barrier has finished closing.
m
ATTENTION: if the holding magnet is not present to set up this
parameter to zero.
PLEASE NOTE: The locking electromagnet is connected to the accessory
power supply. Hence, it is essential to deactivate the energy saving
function to use it
Holding magnet power
This menu allows regulating the power with which the electromagnetic
vacuum gripper becomes blocked.
m
ATTENTION: if the holding magnet is not present, set up this
parameter to zero.
PLEASE NOTE: The locking electromagnet is connected to the accessory
power supply. Hence, it is essential to deactivate the energy saving
function to use it.
Pre-blinking time
Before any barrier movement, blinker will be activated for
warn about the incoming motion
Function deactivated
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5" to 1'00)
The closing pre-flashing time corresponds to
Motor power in opening phase
The displayed value is the percentage of max. motor power
Motor power in closing phase
The displayed value is the percentage of max. motor power
Motor power during opening slow down phase
The displayed value is the percentage of max. motor power
Motor power during closing slow down phase
The displayed value is the percentage of max. motor power
t.PrE
t.PrE
- 55 -
DEFAULT
MEMO
0.0"
0
1.0"
time, to
no
80
80
25
25