PARAMETER
VALUE
SEnS
1.0A - 10.0A
no
rA.AP
0 - 1 00
rA.Ch
0 - 1 00
St .AP
PAUS
ChiU
no
St .Ch
StoP
APEr
St .PA
ChiU
no
PAUS
Ch.AU
no
0.5" - 20'0
DESCRIPTION
Enable the obstacle sensor
This menu allows you to regulate the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the set value, the
controller detects an alarm.
During the opening, an obstacle would cause the arrest of the boom.
During the closing, an obstacle would cause the complete reopening, in
order to free the obstacle.
In both cases the automatic closing comes disabled the second time that
the cycle is interrupted by an obstacle.
If the obstacle is found nearing the of the travel height, is interpreted as a
mechanical arrest
Function deactivated
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
Slow down in closing
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase.
The barrier closes and enters in pause
The barrier immediately starts to reclose
The barrier continues to open (the command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
The barrier closes and the cycle is considered concluded
The barrier reopens
Start command during the pause
This menu allows establishing the behavior of the control units if a Start
command is received while the barrier is opened in pause.
The barrier starts to reclose
The command is ignored
The pause time becomes recharged (
Automatic Closing
In automatic operation, the control unit automatically recloses the barrier
at the end of the preset time
Function deactivated
The barrier recloses after the time set
Ch.AU
)
- 56 -
DEFAULT
MEMO
no
25
25
PAUS
StoP
ChiU
no