PARAMETER
VALUE
Strt
StAn
no
AP.Ch
PrES
oroL
StoP
no
ProS
invE
Foto
no
APCh
CFCh
Ch
Ft.tE
no
Si
DESCRIPTION
Function of input START1 and START2
This menu allows choosing the mode of operation of the input START1
and START2
Standard mode
The Start input commands on the terminal strip are disabled.
The radio command function depending of the mode
Open/Close mode
Dead Man mode
Clock mode
Stop input
The input STOP is disabled
The STOP command set the barrier idle: on the next successive command
START the barrier resumes the motion in the same direction
The STOP command sets the barrier idle: on the next successive START
command makes the barrier resume the motion in the opposite direction
to the previous one
Photocell input
This menu allows programming the behavior in case of participation of the
photocell.
Disabled input (the control unit ignores it)
Input always enabled. The interruption of the photocell during the
opening or closing causes the arrest of the barrier.
At reset the barrier resumes the opening movement.
The interruption when in closed barrier inhibits the opening.
Input enabled in closing and with closed barrier.
The interruption of the photocell during the closing causes the reopening.
Input command enabled only in closing. The interruption of the
photocell during the closing causes the reopening.
ATTENTION: if this option is chosen, it is necessary to disable the
test of photocells
Test of the photocells
Function disabled
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the barrier starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second
StAn
- 58 -
DEFAULT
MEMO
StAn
no
no
no