Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16

Troubleshooting

Problem
Cause
No power at
L
breaker has tripped,
the sensor
is not switched ON,
or break in wiring
L
short circuit
L
low voltage wiring to
power pack is incorrect
Lights do not
L
light level setting is in
switch ON
nighttime mode during
daytime operation
L
lamp burned out
L
power is off
L
breaker has tripped
L
detection zone not
correctly adjusted
Lights do not
L
abundant heat from
switch OFF
fixture is within
detection zone and
keeps lights on as a
result of temperature
change
L
continuous movement in
the detection zone
www.steinel.net
(800) 852-4343
Remedy
L
reset breaker,
check wiring with
voltage tester
L
check for proper
wiring connections
L
check for proper
wiring connections
L
adjust light level
setting
L
replace lamp
L
turn power on at
circuit breaker
L
reset breaker
L
readjust
L
move sensor away
from direct view of
the fixture
L
readjust zone or
apply shroud
Troubleshooting
Problem
Cause
Lights keep
L
switched on light is
switching
within detection zone
ON/OFF
L
low voltage overload on
power pack
Lights switch
L
sensor is detecting
ON without
movement outside of
obvious
the lighting zone
movement
Sensor
L
sensor is in pulse mode
detects
but is not connected to
occupancy
a time delay relay
but turns off
in 2 seconds
www.steinel.net
17
Remedy
L
adjust detection
zone or apply
shrouds, increase
distance
L
reduce the
number of devices
connected to the
power pack
L
adjust zone or
apply shrouds
L
adjust sensor's
time delay or use
with a time delay
relay
(800) 852-4343

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tr 150-mTr 100-aTr 150-a

Tabla de contenido