Status LEDs
A
Readiness to
operate
B
Ethernet
traffic
traffic
C
Recording
D
Recording
status
18
Status
lights up
green
lights up red
flashes red
off
flashes green
off
lights up red
lights up
yellow
flashes red
flashes yellow
Description
System is ready to operate.
Initialization is running
Fault
Undefined status, e.g. operating
voltage not applied
Ethernet data traffic (Traffic)
No Ethernet data traffic (Traffic)
Lights up at each recording for at
least 250 ms
Lights up for 250 ms when trigger
signal is applied
Recording data available in the
memory
System waits for trigger signal
(ready for recording)
Festo P.BE−K−SBO−M 0511NH English