4.3 Trigger signal
The trigger signal is applied via inputs I0 and I1.
The trigger condition is fulfilled when:
there is a 0−signal at I0 and
a 1−signal at I1.
This link enables you to trigger with positive edges as well
as with negative edges. In order to do this, connect the
unused trigger input firmly to the relevant active level
(trigger input I0 to GND or trigger input I1 to +24 V DC).
When the system is ready for recording and is waiting for
the trigger signal, the recording status LED (D) flashes
yellow. If the trigger signal is present, the recording LED (C)
will light up for 250 ms.
Please note
Further information on operating the Compact Vision
System can be found in the help system of the configur
ation software Festo Configuration Tool (FCT).
26
Festo P.BE−K−SBO−M 0511NH English