AIR COMPRESSOR OIL
SPECIFICATIONS
Compressors are factory filled with
CHAMPLUB hydrocarbon based
recip lubricant. This is an ISO 100
non-detergent industrial lubricant
with rust and oxidation inhibitors
specially formulated for
E
reciprocating comporessors. It is
N
recommended this compressor be
G
maintained using this oil for
L
ambient temperatures above 32°F
I
S
CHAMPLUB synthetic is a
H
premium grade diester based
synthetic lubricant providing
excellent performance in high
temperature applications.
Do not mix oil
types, weights or brands.
"Emulsification
of oil (white milky substance)
indicates unsafe accumulation
of moisture and may be
evidence compressor is
oversized for application.
Failure to promptly consult your
local distributor, or Champion
Customer Service, can be
grounds to deny warranty."
NOTES:
1. Normal break-in period of
Champion air compressors is
25 hours.
2. For the first 100 hours of
compressor operation, a careful
and regular check of the oil
level should be made. Maintain
oil level at the full line.
CHANGING TO SYNTHETIC
LUBRICANT
(Applies to diester based synthetic
lubricant only).
If changing to synthetic lubricant
the following steps must be
completed.
1. Compressor must run for a
25 hour break-in period
using ChampLub ISO 100
oil.
2. Thoroughly drain existing oil
from crankcase.
6
3Z410A
3. Fill crankcase with a full charge
of sythetic lubricant.
4. Run compressor for 200 hours.
5. Stop compressor and
thoroughly drain the synthetic
lubricant.
6. Add a full charge of synthetic
lubricant.
7. Compressor now ready to run
for extended period before next
lubricant change.
LUBRICANT
PART
DESCRIPTION
NUMBER
1 Quart Bottle
ChampLub
P13796A
Mineral Lubricant
1 Quart Bottle
ChampLub
P13929A
Synthetic