Air Conditioner Ceiling-Floor
1. INSTALLATION PRECAUTION
•
To install properly, please read this manual at
first.
•
The air conditioner must be installed by qualified
persons.
•
When installing the indoor unit or its tubing,
please follow this manual as strictly as possible.
•
When all the installation work is finished, please
turn on the power only after a thorough check.
•
No further announcement if there is any change
of this manual caused by product improvement.
NOTE
The installor should illustrate to users how to
correctly use and maintain the air-conditioner, as
well as remind users to carefully read and keep
both Installation Manual and Owner's Manual well.
2. INSTALLATION PLACE
The Indoor Unit
•
There is enough roomfor installation and
maintenance.
•
The ceiling is horizontal, and its structure can
endure the weight of the indoor unit.
•
The air outlet and the air inlet are not impeded,
and the influence of external air is the least.
•
The air flowcan reach throughout the room.
•
The connecting pipe and drainpipe could be
extracted out easily.
•
There is no direct radiation fromheaters
The Outdoor Unit
•
There is enough room for installation and
maintenance.
•
The air outlet and the air inlet are not impeded,
and can not be reached by strong wind.
•
The place is dry and ventilative.
•
The support is flat and horizontal and can stand
the weight of the outdoor unit. And no additional
noise or vibration.
•
Your neighborhood will not feel uncomfortable
with the noise or expelled air.
•
There is no leakage of combustible gas.
It is easy to install the connecting pipe or cables.
CAUTION
Location in the following places may cause
malfunction of the machine. (If unavoidable, please
consult your local dealer.)
a. There exists petrolatum.
b. There is salty air surrounding(near the coast).
c. There is caustic gas(the sulfide, for example)
existing in the air (near a hot spring).
d. The Volt vibrates violently(in the factories).
e. In buses or cabinets.
f. In kitchen where it is full of oil gas.
g. There is strong electromagnetic wave existing.
h. There are inflammable materials or gas.
i. There is acid or alkaline liquid evaporating.
j. Other special conditions.
Notes Before Installation
1. Select the correct carry-in path.
2. Move this unit as originally packaged as
possible.
3. If the air conditioner is installed on a metal part
of the building, it must be electrically insulated
according to the relevant standards to electrical
appliances.
NOTE
Remark per EMCDirective 89/336/EEC
For to prevent flicker impressions during the start
of the compressor (technical process), following
installation conditions apply.
1. The power connection for the air conditioner has
to be done at the main power distribution. The
distribution has to be of a low impedance,
normally the required impedance reaches at a
32A fusing point.
2. No other equipment has to be connected with
this power line.
3. For detailed installation acceptance, please
refer to your contract with the power supplier
if restrictions do apply for products like washing
machines, air conditioners or electrical ovens.
4. For power details of the air conditioner, refer to
the rating plate of the product.
5. For any question contact your local dealer.
2
EN