Electrical connection
WARNING
Electrical Shock Hazard
• Disconnect power before servicing.
• Use 8-gauge, solid-copper wire.
• Ground the oven.
Failure to follow these instructions can cause electrical shock, fire, or death. This oven is
manufactured with a neutral (white) power supply wire and a cabinet-connected ground
(green or bare) wire twisted together.
UL-listed or
CSA-approved
conduit
connector
1.
Disconnect power.
2.
Feed the flexible conduit from the oven
through the opening in the cabinet.
3.
Remove the junction box cover, and
install a UL-listed or CSA-approved
conduit connector to the junction box.
4.
Route the oven's flexible conduit to the
junction box through a UL-listed or
CSA-approved conduit connector.
5.
Tighten conduit connector screws.
6.
See the chart on pg. 24 to complete
installation for your electrical
connection.
English 23