Installation instructions
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from the home power supply where codes permit a
3-wire connection.
A
B
C
D
E
F
A. Cable from home power supply
B. Junction box
C. Black wires (normally L1)
D. White wires (normally N-neutral)
E. green wires (normally G-ground)
F. 4-wire flexible conduit from oven
G. Red wires (normally L2)
H. UL listed wire connectors
I. UL-listed or CSA-approved conduit
connector
26
English
1.
Connect the 2 black wires (C) with a
UL-listed wire connector.
2.
Connect the 2 white wires (D) and the
oven's green (bare) ground wire with
G
a UL-listed wire connector.
H
3.
Connect the 2 red wires (G) with a
UL-listed wire connector.
4.
Install the junction-box cover.
I