GYS GYSCAP 500 E Traducción De Las Instrucciones Originales página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Translation of the original instructions
Press the button for 3 seconds to perform a forced start.
A 30 seconds countdown starts.
Start the vehicle as quickly as possible before the capacity is transferred to the battery.
Wait for the GYSCAP 500E to charge itself until the display shows
(Once it's charged, the GYSCAP 500E is ready for a new start)
After switching the GYSCAP 500E off
Disconnect the GYSCAP 500E clamps from the vehicle.
Wind up the cables and put them in the dedicated space.
PROTECTIONS
• These clamps have been designed for maximum protection :
• The clamps are fully insulated.
• Is it protected by a 300 A fuse (ref. 054561)
• A fuse guarantees protection against polarity inversion and short circuits. Replacing it requires manual intervention.
FUSE
300A
• Smart starter management system :
• This system protects the vehicle's on-board electronics, the charger, the battery and the user.
• Protects against: polarity reversals / clamps in short-circuit / deep discharges and voltage selection errors.
GYSCAP 500E
Connect the red clamp (+) to the battery's (+) termi-
nal.
Remove the red clamp (+) from the battery's (+) ter-
minal.
EN
. .
15

Publicidad

Tabla de contenido
loading

Tabla de contenido