SDE5-...
Type
Rated pressure range
Overload pressure (brief )
Setting range:
– Switching pressure
– Hysteresis (mode 2)
– Hysteresis (mode 0, 1, 3)
Repeatability of the switching
pressure
Temperature coefficient
Ambient temperature range
Storage temperature range
Operating voltage range DC
Idling current
Switch output
– Max. output current
– Voltage drop
– Capacitive load max. DC
– Switching times (on/off )
Protective functions
Protection class
Protection class
Max. permitted signal cable
length
Materials
Fig. 25
36
SDE5-D10-...
SDE5-D2-...
0 ... 10 bar
0 ... 2 bar
Max. 15 bar
Max. 6 bar
0 ... 100 % FS (full scale), (recommended working area 5 .. 95 % FS)
0 ... 100 % FS, (recommended working area 5 .. 95 % FS)
2 % FS (set fixed)
Max. ±0.3 % FS
0.5 % FS / 10 K
0 ... +50 °C
-20 ... +80 °C
15 ... 30 V (permitted residual ripple max. 10 %, within the
operating voltage range)
Max. 30 mA
Positive switching (PNP)
100 mA
1.5 V
100 nF
2 ms (typical) / 4 ms (max.)
Incorrect polarity, short circuit/overload (pulsed), induction
voltage
IP40 (as per EN 60529)
III
30 m
– Housing:
PA, POM, PPS (reinforced)
– EDIT button:
VMQ
– Cable coating:
PUR
– Plug/compressed
air connections:
Ms (nickel-plated, chromium-plated)
– Support:
PP
SDE5-V1-...
0 ... -1 bar
Max. 5 bar
Festo SDE-... 0204NH English