1. Dry Extraction
Only extract with a dry fi lter, unit and accessories so that the dust does not adhere and harden. We recommend using a paper fi lter bag if soot, cement,
plaster, fl our or similar substances are extracted. Always use the paper fi lter bag in combination with the fi lter cartridges.
2. Wet Extraction
Extract without a paper fi lter bag. The fi lter cassettes are suitable for wet extraction. The installed sensor switches the motor off when the tank is full.
Empty the unit as outlined in Section 4.
The unit will only be ready for operation again after it has been switched off and switched on again.
- Before emptying, fi rst remove the extraction hose from the liquid.
- Due to the high extraction output and the streamlined shape of the tank, a little water may escape from the hose after the unit has been switched off .
- For the subsequent dry extraction phase, use a dry fi lter. In case of frequent changes between dry and wet extraction, we recommend using a second fi lter set,
preferably polyester fi lter cassettes.
3. Cleaning the fi lter
The extraction unit is fi tted with an electro-magnetic fi lter cleaning device which can shake off any dust adhered to the folded fi lter cassettes.

3.1. Manual cleaning

The vibration function (switch setting R or RA /switch
the warning signal sounds or when the extraction output sinks.
3.2. Automatic cleaning (automatic vibration)
Filter cleaning is performed (switch setting RA/switch
4. Emptying the tank
Only permitted with dusts with Workplace Explosure Limits > 1mg/m
Switch off
a, disconnect plug
2
Take top section
and extraction hose from the tank
1
Empty the tank.
5. Paper fi lter bag
To insert or remove the fi lter bag/emptying bag, remove the top section
To do this, open the side locks
9
Only use the paper fi lter bag for dry extraction.
5.1. Inserting the paper fi lter bag
25 and 50 litre tank
Push the fl ange over the extraction opening
Turn the knob in the extraction opening with the marking
Operating the slide valve:
Push the slide valve from inside to the outside
5.2. Exchanging the paper fi lter bag
Carefully pull the fl ange from the extraction connections and close the fl ange.
Turn on the motor before putting down to ensure that any falling suspended dust can be extracted.
Dispose of the vacuumed material as per the statutory regulations.
5.3. Plastic emptying bag
Only the M vacuum cleaners with the special tanks and rotary valve in the suction opening are suited for using plastic emptying bags.
Turn the rotary valve with the round label upwards in the extraction opening
3M Instruction Manual
75-078_DustExtraction.indd 9
75-078_DustExtraction.indd 9
OPERATION (WET AND DRY EXTRACTION)
2
a ) should be activated at the latest when the volume fl ow display
a) automatically during the next working break when the minimum volume fl ow level is reached.
2
3
.
, open snap locks
.
6
9
.
7
1
.
4
to the top. Push the fl ange over the extraction opening.
, turn by 180°
(see marking
1
2
.
) and press from outside through the extraction pipes to the inside again
4
.
4
7
2
c (warning lamp) lights up or when
.
3
16.03.2010 10:47:43
16.03.2010 10:47:43
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido