Optional Stand
An optional stand is available for the scanner which can be per-
manently attached to a wall or countertop. After locating the
stand in an optimal position, the scanner (along with the stand)
can be detached for portable use by lifting the entire unit as
shown below.
Power Supply
Models require
ited Power Source (LPS). For the safety certification to be
valid, class III input power sources must be IEC/EN60950-1
(EN 60335-series, EN 60065 or relevant) approved.
Input: 100 - 240 VAC Output: 5 VDC
System Input Voltage
Input: 4.5 - 14.0 VDC
How to Scan
barcodes can be presented to the scanner while it is resting on
the counter or in the optional stand, or the scanner/mount can
be lifted and held as shown.
1. Power Off the Terminal (POT) units do not require a power sup-
ply.
2
1
either a Listed class II or class III with a Lim-
Optional Scan Button Shown
*Optional Stand
Max. Current: 2.5 A
Max. Power: 12.5 W
Max. Power: 2.5 W
Magellan™ 1100i