Samoa 366 000 Guía De Servicio Técnico Y Recambio página 5

Contador electrónico
Ocultar thumbs Ver también para 366 000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

After the calibration process you will obtain precision
within the range of ±0,5% with the meter. If the meter
exceeds this range it could be due to the following:
• Unsuitable container used for the calibration.
The calibration process is semi-automatic. To start the
process, the meter must be in partial meter mode (fig. 14)
and is accessed by simultaneously pressing the buttons
ON/RESET and SELECT for 3 seconds (fig. 15). After
releasing the buttons the current calibration factor is
shown on the meter (fig. 16).
3"
Fig. 14
If the screen does not show the correct measuring unit
(fig. 16) press the SELECT button (fig. 17) successively
until displaying the required unit (fig. 18).
Press ON/RESET (fig. 19) to start the calibration
process (fig. 20).
Fig. 17
Fig. 18
It now starts to release the desired volume into the
container. Remember that you must release at least 1
litre to perform a good calibration. In the example
shown in the figures it is assumed that 2 litres are
released according to the reading on the calibrated
container and that the meter records 2,1 litres (fig. 21).
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Calibration capacity
Calibration procedures
Fig. 15
Fig. 16
Fig. 19
Fig. 20
Fig. 21
Calibration
• The container is not empty before the calibration.
• Air in the fluid which has not been completely removed.
• The values are not properly introduced into the
calibration process.
To administer the real quantity released (which is that
measured in the calibrated container or scales), press the
ON/RESET button for 1 second (fig. 22). The digits start
to flash (fig. 23) indicating that the value shown can be
modified. Each press of the ON/RESET button increases
the value by 0,1 litres and each press of the SELECT
button (fig. 24) reduces this value by 0,1 litres (fig. 25).
1"
Fig. 22
Once the real value released is set (fig. 25) press the
ON/RESET button for 1 second (fig. 26). The meter
shows the new stored calibration factor (fig. 27) and
then exits the calibration process. The screen shows
the partial meter with the units set during the
calibration process (fig. 28).
If, during any phase of the calibration process, you wish
to exit without saving the changes made you must
press the SELECT button for 1 second. Likewise, if 30
seconds of inactivity elapse during the process, the
meter switches off automatically and exits the calibration
process without storing the data.
1"
Fig. 26
Fig. 23
Fig. 24
Fig. 27
R. 09/14 836 826
Fig. 25
Fig. 28
5

Publicidad

Tabla de contenido
loading

Tabla de contenido