3 Installation
Routing
Possible cables (depending on unit type and installed options)
a
Low voltage
b
High voltage power supply
c
High voltage control signal
4
Fix the cable with cable ties to the cable tie mountings to ensure
strain relief and to make sure that it does NOT come in contact
with the piping and sharp edges.
CAUTION
Do NOT push or place redundant cable length in the unit.
3.5.3 To connect the main power supply
1
Connect the main power supply.
In case of normal kWh rate power supply
X5M
X6YB
X2M
X6Y
X6YA
X1M
1 2 3
1 2 3
Legend: see illustration below.
Installation manual
6
User interface
Domestic hot water tank thermistor (option)
Power consumption digital inputs (field supply)
Outdoor ambient temperature sensor (option)
Indoor ambient temperature sensor (option)
Electrical meters (field supply)
Interconnection cable
Normal kWh rate power supply
Preferential kWh rate power supply
Power supply for backup heater
Power supply for bottom plate heater (option)
Power supply for booster heater (to indoor unit)
Power supply for booster heater and thermal protection (from indoor unit)
Preferential power supply contact
Heat pump convector (option)
Room thermostat (option)
3-way valve
Shut-off valve (field supply)
Domestic hot water pump (field supply)
Alarm output
Changeover to external heat source control
Space heat/cool operation control
X1A X19A
30 31
a
In case of preferential kWh rate power supply
X5M
3 4
X6YB
X2M
X6YA
X1M
c
b
L N
1 2
S1S
L N
1 2 3
a Interconnection cable (=main power supply)
b Normal kWh rate power supply
c Preferential power supply contact
2
Fix the cable with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, the necessity
of separate normal kWh rate power supply to indoor unit (b)
X2M30/31 depends on the type of preferential kWh rate
power supply.
Separate connection to the indoor unit is required:
if preferential kWh rate power supply is interrupted when
active, OR
if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
X1A
X19A
X6Y
30 31
a
3
RHBH/X04+08+16CA
Rotex HPSU low temperature Bi-Bloc
4P330419-1A – 2012.11