Troubleshooting - DeVilbiss FLG4 Serie Manual De Servicio

Pistola pulverizadora flg4 alimentada por gravedad y sistema dekups de cubetas desechables
Ocultar thumbs Ver también para FLG4 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DeKUPS
ACCESSORIES
®
U.S. Patent numbers 6,820,824 and 7,374,111 owned by 3M Innovative Properties Co.
Additional U.S. Patents: Nos. 7,380,680; 7,354,074; 7,353,964; 7,350,418; 7,344,040; 7,263,893; 7,165,732; 7,086,549.

TROUBLESHOOTING

CONDITION
Heavy top or
bottom pattern
Heavy right or left
side pattern
Heavy center pattern
Split spray pattern
Jerky or fluttering spray
Unable to get round spray
*Most common problem.
SB-2-779-J (9/2017)
CAUSE
Horn holes plugged.
Obstruction on top or bottom of fluid tip.
Cap and/or tip seat dirty.
Left or right side horn holes plugged.
Dirt on left or right side of fluid tip.
Remedies for the top-heavy, bottom-heavy, right-heavy, and left-heavy patterns:
1. Determine if the obstruction is on the air cap or the fluid tip. Do this by making a test spray
pattern. Then, rotate the cap one-half turn and spray another pattern. If the defect is inverted,
obstruction is on the air cap. Clean the air cap as previously instructed.
2. If the defect is not inverted, it is on the fluid tip. Check for a fine burr on the edge of the fluid tip.
Remove with #600 wet or dry sand paper.
3. Check for dried paint just inside the opening; remove by washing with solvent.
Fluid flow too high for atomization air.
Material flow exceeds air cap's capacity.
Spreader adjustment valve set too low.
Atomizing pressure too low.
Material too thick.
Atomization air pressure too high.
Fluid flow too low.
Spreader adjusting valve set too high.
*Loose or damaged fluid tip/seat.
Material level too low.
Container tipped too far.
Obstruction in fluid passage.
Dry or loose fluid needle packing nut.
Spreader adjustment screw not seating
properly.
Air cap retaining ring loose.
7 / 9
CORRECTION
Clean. Ream with non-metallic point.
Clean.
Clean.
Clean. Ream with non-metallic point.
Clean.
Balance air pressure and fluid flow. Increase spray
pattern width with spreader adjustment valve.
Thin or lower fluid flow.
Adjust.
Increase pressure.
Thin to proper consistency.
Reduce at transformer or gun.
Increase fluid flow (increases gun handling speed).
Adjust.
Tighten or replace.
Refill.
Hold more upright.
Backflush with solvent.
Lubricate or tighten.
Clean or replace.
Tighten.
EN
DPC-31
www.carlisleft.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Flg-cng-115Flg-hvg-315

Tabla de contenido