8. MAINTENANCE
AQUA-BASE
The
unit must be maintained regularly in order to avoid the occurrence of defects which could alter its efficiency, its operating
and its reliability. The intervals between maintenance of the
81. MAINTENANCE SCHEDULE
OPERATION
Replacement of filter cartridge
Replacement of the belt
Checking oil level
Oil change
Cleaning the cell
Cleaning the membranes
Checking pressure of the dampner
On this basis the user will adapt his own maintenance schedule, which will depend on his personal use of the unit.
82. SPARE PARTS FOR ONE YEAR Réf. 752046-7
The spare parts set, for one year
QTE/QTY
REFERENCE
2
711014
1
752038
1
752039
1
752037-EXP10
83. REPLACEMENT OF THE FILTER CARTRIDGE (See Fig. 9p32)
- Open the filter by unscrewing the tightening nut using the filter spanner.
- Free the used cartridge by setting down the filter bowl.
- Replace the used cartridge with an genuine new one.
- Wipe and lightly oil the seal with food grease.
- Reset the filter after having checked the cartridge position.
- Screw the tightening nut with the filter spanner.
84. REPLACEMENT OF THE BELT (See Fig. 10p32)
- Loosen the 4 pump fastening screws.
- Slacken the belt by drawing the pump closer to the motor.
- Replace the used belt with a new genuine one.
- Draw it tight moderately by separating the pump from the motor (1daN tension is sufficient) DO NOT OVERTIGHTEN.
- Tighten the 4 pump tightening screws energetically.
85. OIL LEVEL (See Fig. 11p32)
- As the pump is placed horizontally, the oil level should be visible between the centre (red point) and the top of the gauge.
- If necessary, adjust the level by using exclusively the original oil
- Check that the air-intake hole of the pump casing, placed in the centre of the filler cap, isn't clogged.
86. HP PUMP OIL CHANGE (See Fig. 11p32)
This should be carried out every year and each time that an anomaly is detected: strong persistent emulsion (foam) visible via the gauge even
after stopping of the unit, accidental introduction of water in the pump casing, accidental and prolonged over speed of the pump,...
- Open the filling plug and check that the air-intake hole of the pump casing, placed in the centre of the filler cap, isn't clogged. Clear it if
necessary.
- Loosen the oil change plug, take it out and wait until all the oil contained in the pump casing has drained.
- Replace the oil change plug and fill up with oil using only original oil
- Shut the HP pump filling hole.
87. CLEANING THE SALINITY CELL (See Fig. 12p32)
The cleaning of the cell should be carried out every year and each time an anomaly has been caused by bad operating: faulty salinity control,
discharge anomaly,...
- Unscrew the cell lock nut,
- Take the cell out of its housing,
- Clean the cell electrodes with a brush under running water and, if necessary, using a domestic detergent,
- Rinse the cell with running water and put it back into its housing,
- Screw the lock nut.
AQUA-BASE
FREQUENCY
Recommended
When it is clogged
When it is worn
Every week when used regularly
At 50 hours, then every 500 hours
Every 1000 hours
Once a year
AQUA-BASE
ref 752046, contains all the necessary parts for maintaining the
DESIGNATION
Cartouche de filtre
Huile pompe HP (0.5 litre)
Solution de stockage
Kit nettoyage A+B
unit depend on the frequency and conditions of use.
DESCRIPTION
Filter element
Hp pump oil (0.5 litre)
Preservation chemical
Cleaning kit A+B
AQUA-BASE,
Ref. 752038.
AQUA-BASE,
Ref. 752038, and controlling the level with the gauge.
AQUABASEXA221-222-223 FR-GB-ES 01-2007.doc
NECESSARY SPARE
PARTS
Minimum
1 year
711014
741045
1 year
752038
1 year
1 year
752037-EXP10
1 year
AQUA-BASE
desalination unit.
FR/GB/ES Page 16/16
VERSION 01/07