8. PROBLEMS AND SOLUTIONS

You can solve many simple problems with your temperature control cellar, thus avoiding having to
contact your after-sales department. Try the following suggestions:
PROBLEM
Appliance not running
Not cold enough
No interior light
The appliance seems unusually noisy
The door does not close correctly
The LED does not light
LED display error
The fans are not running
Replacing light
This appliance consists of light-emitting diodes (LEDs). This type of diode cannot be changed by the
consumer. The lifetime of these LEDs is normally sufficient for no change to be made. If however, and
despite all the care taken during the manufacture of your chambrage cellar, the LEDs were defective,
please contact your after-sales service for any intervention.
POSSIBLE CAUSE
 Check the voltage of the installation
 Check your circuit breaker
 A fuse has blown
 Check the temperatures set
 The ambient temperature means that the
temperatures need to be adjusted
 The door is being opened too frequently
 The door is not properly closed
 The door seal is not sealing correctly
 Insufficient
free
appliance
 Contact your after-sales department
 Check that the appliance is level
 Check that a piece of paper or part of the
packaging has not remained trapped inside
 Check that the appliance is level
 The doors have been reversed and
incorrectly fitted
 The seal is in a poor condition
 The feet have "moved"
 The control panel is defective
 Printed circuit board problem
 Mains plug problem
In such cases call a qualified professional
 Poor display quality
 Temperature does not display
In such cases call a qualified professional
 Control panel to be replaced by a qualified
professional