AL-KO SUB 6500 Manual Original De Instrucciones página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Help in case of malfunctions
Malfunction
Motor does not
run
Pump running but
des not feed.
Feed rate too low
If the faults cannot be rectified, please contact our customer service department.
ADVICE
467 769_a
Possible cause
Impeller blocked
Thermal protection switch has swit-
ched off.
No mains power.
Float switch does not switch off when
the water level rises.
Air in pump housing.
Blockage on the suction side.
Pressure line closed off.
Pressure hose kinked.
Hose diameter too small.
Blockage on the suction side.
Feed head to high.
Solution
Remove dirt in the suction area.
Clean with a suitable tool through the
opening at the back of the motor hou-
sing.
Wait until the thermal protection switch
on the immersion pump switches on
again. Take note of the maximum tem-
perature of the conveying medium.
Have the immersion pump inspected.
Check the fuses, have the power sup-
ply checked by a qualified electrician.
Send the immersion pump to an AL-
KO service facility.
Vent the immersion pump by holding it
at an angle.
Remove dirt in the suction area.
Open the pressure lone.
Extend the pressure hose.
Use a bigger pressure hose.
Remove dirt in the suction area.
Observe max. feed head, see technical
data!