5.3
Mounting the product
Verify that the ambient temperature is not exceeded.
Verify that the product is not mounted the product on top of or next to a
non-insulated boiler part, above opening dampers at furnaces or to the
flue gas pipe.
Verify that the float housing points vertically to the top.
LEAKS AT PRODUCT
Do not use hemp or Teflon tape for sealing.
• Verify that you use a screwed pipe connection as per DIN 3852 with cylindri-
cal thread (G thread) and seal it with a flat gasket or with suitable glue.
Failure to follow these instructions can result in equipment damage.
Mounting
A
NOTICE
1. Mount the product to the
boiler casing using the
enclosed bracket and four
self-tapping screws.
2. Use the bracket as a tem-
plate when screwing in the
self-tapping screws. The
arrow (A) must point
upwards).
FloCo-Top-1K
EN
15