RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul
or damage the lower end at the next start-up. Place
suction tube into a 1 qt. (0.95 liters) or more container
of fresh iltered water. Flow fresh water through the
injector by operating until container is empty. This
procedure is not needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt, lies, feathers and
other lying debris from entering the container.
Rinse container thoroughly and often. Do not mix
chemicals together that might react and cause a
precipitate. Use FILTERED luid when illing container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean ilter
screen (#27) and suction tube (#25) as necessary
by rinsing in fresh water. Replace if necessary. Keep
ilter screen off bottom of solution container to
prevent dirt and precipitate from clogging ilter.
CLEAN INLET FILTER
Clean or replace inlet ilter as required to increase
the life of the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by
using the three valve bypass (preferred) or turn the
On/Off lever on the top of the injector to the off position.
STORAGE
For extended storage, rinse injector (see "Rinse
Injector After Each Use") and place underwater
in a container. Apply monthly, <0.1 oz. (29 ml) of
chlorine bleach to avoid algae growth.
KEEP FROM FREEZING.
English: 10
Remote Injecting
Remote Injector Kit
Is recommended for the following:
Injectors In a Series:
When injecting multiple chemical injections, using two
or more injectors. Each injector adds chemical to the
luid(water) system, while bypassing the next injector and
eliminating the potential damage to that injector (see Fig.
6). To prevent mineral buildup within the body of the unit.
Use when injecting chemicals that cause minerals to
precipitate from luid.
Fig. 6
Remote Injector
NOTE: when mixing more than one chemical, always
Kit shown in a
refer to your chemical manufacturer information guide
series.
for proper application. Contact your local distributor or
Dosmatic customer service for information or to order.
Maintenance
Reference numbers refer to Page 12 - 19
MiniDos (0.4%)
& (0.4) PAA
Refer to pages
13 & 14
MiniDos (1%)
Refer to page 15
MiniDos (2.5%)
& (5%) Refer to
pages 16 & 17
MiniDos (10%)
Refer to page 18
MiniDos (20%)
Refer to page 19
(not included)
Kit Part Numbers
Perform these maintenance
procedures to extend the life of your unit.
Every
Every
3 - 6 Months
6 - 12 months
1. Clean seal area
1. Replace #17 O-ring
(#13).
and #51 Shaft Assembly.
2. Check #17 O-ring,
2. Clean and/or replace
#51 Shaft Assembly,
#13 Check Poppet, #11
clean and/or replace
Suction Tube Fitting.
as necessary.
Every
Every
3 - 6 Months
6 - 12 months
1. Clean seal areas
1. Replace #17 O-ring
(# 17, 14 & 13).
and #44 Dosage Piston.
2. Check #17 O-ring,
2. Clean and/or replace
# 68 Cylinder, clean
#13 Check Poppet, #11
and/or replace as
Suction Tube Fitting.
necessary.
Every
Every
3 - 6 Months
6 - 12 months
1. Clean seal areas
1. Replace #17 O-ring
(# 17, 14 & 13).
and #44 Dosage Piston.
2. Check #17 O-ring,
2. Clean and/or replace
#37 Cylinder, clean
#13 Check Poppet, #11
and/or replace as
Suction Tube Fitting.
necessary.
Every
Every
3 - 6 Months
6 - 12 months
1. Clean seal areas
1. Replace #17 O-ring
(# 17, 14 & 13).
and #44 Dosage Piston.
2. Check #17 O-ring,
2. Clean and/or replace
#37 Cylinder, clean
#13 Check Poppet, #11
and/or replace as
Suction Tube Fitting.
necessary.
Every
Every
3 - 6 Months
6 - 12 months
1. Clean seal areas
1. Replace #17 O-ring
(# 17, 14).
and #44 Dosage Piston.
2. Check #17 O-ring,
2. Clean and/or replace
#7 Cylinder, clean
#60.
and/or replace as
necessary.
011762
Replace as
necessary
1. #37 Cylinder
2. #17 O-ring
3. #51 Shaft
Replace as
necessary
1. #68 Cylinder
2. #14, #17 O-ring
3. #51 Shaft
4. #44 Dosage
Piston
Replace as
necessary
1. #37 Cylinder
2. #14, #17 O-ring
3. #52 Shaft
4. #44 Dosage
Piston.
Replace as
necessary
1. #37 Cylinder
2. #14, #17 O-ring
3. #52 Shaft
4. #44 Dosage
Piston
Replace as
necessary
1. #7 Cylinder
2. #14, #17 O-ring.
3. #44 Dosage
Piston