Troubleshooting - DOSMATIC MiniDos Serie Manual De Operación

Tabla de contenido

Publicidad

New Install - Always Pressure Up Slowly (Follow start up on page 9)
Problem
Fluid not lowing through unit
No Clicking
Sound
Fluid lowing through unit
Injector in Operation or After Scheduled Maintenance
Problem
Main Piston Assembly #9 worn
Cover #1 or main body #40 worn
or scored
No Clicking
On/Off Lever in off position
Sound
By-Pass Valve not closed
Dirty or plugged inlet ilter
#17 Worn or not seated properly
Problem
Suction tube #25 (#60 - 20%) or
suction tube itting #11 cracked,
loose, leaking or clogged suction
tube ilter.
Dosage piston #44 worn or
Clicking
installed incorrectly, inner cylinder
Sound
#37 (#68 - 1% & #7 - 20%) worn
No Suction Of
O-ring retainer #82 (#15 - 10% &
20%) installed incorrectly
Solution
O-ring seat #14 or dosage piston
#44 damaged or worn
Check valve #13 (#60 - 20%)
leaking.
Problem
#44 Dosage Piston worn
#37 (#7 - 20%) Inner Cylinder worn
Clicking
Unit operates at high-low and not
Sound.
at low low
Under
Main Piston Assembly #9 worn
Injecting
Cover #1 or main body #40 worn
or scored
Problem
Check valve #13 leaking
Fluid
Re-illing
Washer seal on #13 is swollen or
Solution Tank
chemical attack
Hose Kit #60 (20%) leaking

Troubleshooting

Cause
Are the red plugs at the inlet, outlet and suction tube itting openings removed?
Is the unit installed backward? The arrow on the unit must point in the
direction of the luid low.
Has the new injector been stored for an extended period. If so, submerge the
injector in room temperature water for 24 hours so that the working parts can
reabsorb luid and swell back to the proper size.
If still not clicking, do not open the upper body. Call Dosmatic Customer
Service.
Fluid rate is below or exceeds rated service low of injector. (See Speciications
page 6).
If below increase low rate, if above, reduce low rate.
Operating pressure exceeds maximum limit. Install a pressure reducer valve.
(See Speciications for maximum low rate page 6).
On/Off Lever in off position. Place the On/Off lever switch to the ON position.
By-Pass Valve not closed. Check and set valve to the OFF position.
Cause
Replace # 9 Main Piston Assembly. Clean luid ilter.
Replace and install or clean luid ilter.
Place the On/Off lever switch to the ON position.
Set Valve to the closed position.
Ensure mesh size is correct for proper iltration. Clean ilter.
Re-seat #17 or replace.
Cause
Check for proper it, replace and/or clean as necessary.
Replace. Ensure during maintenance replacement that #44 dosage
piston was installed correctly lared-end up.
Install correctly.
Replace, on 0.4% models replace #51 Shaft Assembly.
Clean & replace as necessary.
Cause
Replace, on 0.4% models replace #51 Shaft Assembly.
Replace.
Replace #17 O-ring.
Replace # 9 Main Piston Assembly. Clean luid ilter.
Replace and install or clean luid ilter
Cause
Check seat area on suction tube itting #11. Check valve and seal must
it loose in the suction tube itting. Clean seal and inside itting for debris.
Replace with new check valve assembly.
Replace
Solution
Solution
Solution
Solution
.
Solution
English: 11