Honeywell TH8320WF Manual Del Usario página 5

Ocultar thumbs Ver también para TH8320WF:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

System setup
Function
0300
Manual/Auto
Changeover
0310
Auto changeover
deadband
0320
Temperature For-
mat (°F/°C)
0330
Automatic Daylight
Saving Time Ad-
justment
Remote Temp
0340
Sensor
Dual Fuel Heat
0346
Pump Upstage to
Furnace Timer
Droop Temperature
0347
(Steady State)
0349
Backup Heat
Manual Droop Tem-
perature
0350
Heat Pump Com-
pressor Lockout
Heat Pump Aux
0360
Lockout
0500
Filter Change
Reminder
The reminder
appears after
selected number of
days run time not
actual time.
Furnace filter
0502
for Run time
0510
Humidifier Pad
Replacement Re-
minder
0520
UV Lamp Replace-
ment Reminder
Settings & Options
0
Manual changeover (Heat/Cool/Off).
1
Automatic changeover (Heat/Cool/Auto/Off). Automatically turns on Heat
or Cool based on room temperature. Note: System maintains minimum
3°F difference between heat and cool settings.
3
Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)])
0
Fahrenheit
1
Celsius
0
Off
1
On
0
None
1
Outdoor for Display
2
Outdoor for Control
3
Remote Indoor
0
Disabled
1
30 minutes
3
60 minutes
5
1.5 hours
6
2 hours
7
3 hours
8
4 hours
2
°F (1.0 °C)
[Other options: displayed in °F or °C]
0
Comfort (Off)
1
Economy
0
Off
[Other options: displayed in °F or °C]
0
None
[Other options: displayed in °F or °C]
0
Off (no reminder)
1
Reminder after 10-day run time (about 1 calendar month)
2
Reminder after 30-day run time (about 3 calendar months)
3
Reminder after 60-day run time (about 6 calendar months)
4
Reminder after 90-day run time (about 9 calendar months)
5
Reminder after 120-day run time (about 1 calendar year)
6
Reminder after 180-day run time (about 18 calendar months)
7
Reminder after 270-day run time (about 2 calendar years)
8
Reminder after 365-day run time (about 3 calendar years)
0
Counts both heat and cool
1
Counts cool only
0
Disabled
1
30-day run time (about 3 months)
2
60-day run time (about 6 months)
3
90-day run time (about 9 months)
0
Disabled
1
365 days
2
730 days
9
5 hours
10
6 hours
11
8 hours
12
10 hours
13
12 hours
14
14 hours
15
16 hours
5
69-2733EFS—01

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Visionpro th8320wf