4. Flare Connections: Firmly hold the copper pipe in a die
with the dimensions as in the following table.
15 SEER & 19 SEER
Pipe size
Model
Gas
Liquid
MSC24*
5/8''
3/8''
MSH24*
(Ф15.9)
(Ф9.52)
Outdoor Diameter
(Inches & mm)
1/4" (6.35)
3/8" ( 9.52)
1/2" (12.7)
5/8" (16.0)
Bar
Copper pipe
Clamp handle
5. Tightening the connection:
Align the center of the pipes and finger-tighten the flare
nut. Using a spanner and torque wrench (Figures 20 &
21) continue tightening the flare nut until the nut is firmly
on the pipe.
ft.
B
A
(m)
ft. (m)
ft. (m)
16.5
33
82
(5)
(10)
(25)
A (inches & mm)
Max
Min
3/64" (1.3)
1/32" (0.7)
1/16" (1.6)
3/64"( 1.0)
1/16" (1.8)
3/64" (1.0)
3/32" (2.2)
3/32" (2.0)
Handle
Bar
Yoke
Cone
Red arrow mark
Figure 19
Outdoor
Diameter (mm)
1/4" (Φ 6.35)
3/8" (Φ 9.52)
1/2" (Φ12.7)
oz./ft.
(g/m)
0.423 (40)
5/8" (Φ16.0)
Do not over-tighten. Excessive torque can
break the nut and/or crimp the pipe.
7
Additional
Tightening
Tightening
Torque
Torque
11 lb.-ft.
11.8 lb.-ft.
1500 (N-cm)
1600 (N-cm)
18.5 lb.-ft.
19.2 lb.-ft.
2500 (N-cm)
2600 (N-cm)
26 lb.-ft.
26.5 lb.-ft.
3500 (N-cm)
3600 (N-cm)
33 lb.-ft.
34.5 lb.-ft.
4500 (N-cm)
4700 (N-cm)
Figure 20
Figure 21