Accessing the DL3 Datalogger with the RPT Para-
meterisation Tool via VBus.net
To use RPT, the VBus access over local network has to be enabled.
In order to activate the VBus access, proceed as follows:
Î In the main menu Device Config, select the submenu Remote Access.
Î On the VBus access over local network tab, in the dropdown menu Local
network access enabled? select Yes.
Î On the Remote access over Internet tab, in the dropdown menu Use
VBus.net for remote access? select Yes.
With a VBus.net account you can easily use RPT in order to parameterise the
controller:
Î In the VBus.net menu My Devices, click on Edit.
Î On the General settings page, tick the option Allow parameterization
using the via address and the RESOL Parameterization Tool (RPT).
Î Enter the Via tag from the VBus.net menu item General settings into the
RPT field URL/IP.
Î Enter the password into the Password field.
Î Click on Connect.
8

Firmware update with SD card

New firmware versions extend the functional range and enhance the operation.
The current software can be downloaded from www.resol.de/firmware.
In order to run a firmware update over the SD card slot, proceed as follows:
Î Download the firmware from the Internet (www.resol.de/firmware) and save
it to your PC.
Î Extract the file.
Among the extracted files there is a folder called SDCARD.
Î Insert an SD card formatted with the FAT32 format into the PC.
Î Copy the contents of the SDCARD folder onto the first level of the SD card.
34
There should then be a folder structure called RESOL/DL3 on the SD card, con-
taining the firmware file.
Î Remove the SD card from the PC and insert it into the SD card slot of the
DL3.
The operating control LED starts flashing green.
The message Do not remove SD card! appears.
Î Wait until the operating control LED is permanently green.
The menu item Update appears.
Î Select Update and confirm with Yes.
The operating control LED starts flashing green and then red/green.
The message Restarting device appears.
The operating control LED starts flashing green.
The message Do not remove SD card! appears.
When the firmware update is completed, the menu item Copy data appears.
9

Data export

There are 2 different ways to export logged data from the DL3 Datalogger:
1. Export logged data onto an SD memory card. The data are stored as a VBus
format file and can be read out on a computer using the RESOL ServiceCenter
software.
2. Export logged data onto a computer over the web interface. Different file
formats can be selected.
Note
Information about exporting data over the Web interface can be found in
the detailed manual on the CD included.
9.1

Data export over SD card

In order to copy data onto an SD card, proceed as follows:
Î Insert the SD card into the SD card slot
The operating control LED flashes (green):
The card has been recognised and data are being transferred.
The operating control LED is permanently green:
The transfer is completed. The card can be removed.
®