Symbols Used In The Manual - Crown CT13545 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
sult their physician and the medical implant manufac-
turer before operating this power tool�
Power tool use and care
• The persons with lowered psychophysical or men-
tal aptitudes as well as children can not operate the
power tool, if they are not supervised or instructed
about use of the power tool by a person responsible
for their safety�
• Do not force the power tool. Use the correct
power tool for your application� The correct power
tool will do the job better and safer at the rate for which
it was designed�
• Do not use the power tool if the switch does
not turn it on and off. Any power tool that cannot be
controlled with the switch is dangerous and must be
repaired�
• Disconnect the plug from the power source
and / or the battery pack from the power tool be-
fore making any adjustments, changing accesso-
ries, or storing power tools� Such preventive safety
measures reduce the risk of starting the power tool
accidentally�
• Store idle power tools out of the reach of chil-
dren and do not allow persons unfamiliar with the
power tool or these instructions to operate the
power tool. Power tools are dangerous in the hands
of untrained users�
• Maintain power tools. Check for misalignment or
binding of moving parts, breakage of parts and any
other condition that may affect the power tool's op-
eration. If damaged, have the power tool repaired
before use. Many accidents are caused by poorly
maintained power tools�
• Keep cutting tools sharp and clean. Properly
maintained cutting tools with sharp cutting edges are
less likely to bind and are easier to control�
• Use the power tool, accessories and tool bits
etc. in accordance with these instructions, taking
into account the working conditions and the work
to be performed. Use of the power tool for operations
different from those intended could result in a hazard-
ous situation�
• Keep handles and grasping surfaces dry, clean
and free from oil and grease. Slippery handles and
grasping surfaces do not allow for safe handling and
control of the tool in unexpected situations�
• Note that when you operate a power tool, please
hold the auxiliary handle correctly, which is helpful
when controlling the power tool� Therefore, proper
holding can reduce the risk of accidents or injuries�
Service
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power tool
is maintained�
• Follow instruction for lubricating and changing ac-
cessories�
Safety guidelines during power tool op-
eration
Before commencing operation
• It is obligatory to switch on a power tool to the socket
that is properly grounded by grounding contact�
• Use grinding discs safe rotation ratio of which is big-
ger than rotation ratio of spindle of power tool� Follow
manufacturers' recommendations regarding use of
tools and accessories�
• Do not use grinding discs that have cracks, cleav-
ages, distortions, as well as grinding discs causing in-
creased vibration of power tool�
• Protect grinding discs from shock, prevent them
from greasing�
• Do not use grinding discs dimensions of which (out-
er diameter and bore diameter) differ from the recom-
mended ones�
• Never work with protection devices dismounted�
Damaged protection devices must be replaced imme-
diately�
During operation
• Apply the workpiece to the grinding disc only when
the disc reaches its maximum rotation speed�
• Do not use the side surface of grinding disc for
grinding�
• Do not stop the motor of power tool when it is en-
ergized�
• Beware of recoil (sudden push back) of the workpiece
while operating the power tool� Recoil can be caused by
non-compliance with operation recommendations, too
abrupt apply of the workpiece to the grinding disc, etc�
In order to minimize the risk of recoil always follow the
recommendations during operation of the power tool�
• During operation of the power tool stay straight and
hold the workpiece with both hands on the supporting
plate�
• Keep your hands safely distant from the rotating
grinding discs and never touch them, otherwise it may
result in severe injuries�
• When processing small blanks, use clamping devices�
• During operation watch the position of a power cable
(it should always be positioned behind the power tool)�
Do not allow it to whip around your legs or arms�
• Dust generated during operation may be a hazard to
your health, inflammable or explosive; clean your work-
ing place in time and use means of individual protection�
• Operation may produce sparks and small metal par-
ticles, which can cause injury to the operator or to the
bystanders� Always wear means of individual protec-
tion (goggles and protective mask), as well as arrange
your working place in a proper way�
• Do not work materials containing asbestos� Asbes-
tos is considered carcinogenic�
• If the power supply suddenly cuts during operation,
immediately move on / off switch into off in order to
prevent accidental starting of the power tool�
• Avoid overheating your power tool, when using it for
a long time�
After finishing operation
• After turning of the power tool off, the grinding disc
continues to rotate for some time due to inertia� This is
why the power tool should be put aside only after its
rotating parts come to a full stop�
• It is strongly prohibited to slow down the rotation of
slowing grinding discs by applying force to the side
surface of discs�

Symbols used in the manual

Following symbols are used in the operation manual,
please remember their meanings� Correct interpreta-
English
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ct13545lCt13546Ct13546lCt13547Ct13547l

Tabla de contenido