golmar T4502ML Manual De Instalación página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MODULE PROGRAMMING
Use this operation mode to connect the module to a C4Plus access control system.
In this case, the C4Plus relays will be activated instead of the module internal relay.
Use the PIN code to enter into programming mode, as it's described on page 28.
In case of valid code, the display will show the selected
In this mode, the cards are recorded on the C4Plus memory instead of the memory module.
DIRECTORPlus software will be necessary to manage the C4Plus memory. However, one
of the C4Plus relays must be assigned to the proximity reader module.
Use "UP" or "DOWN" arrows to select a C4Plus relay.
To exit from the programming mode, wait 20 sec.
C
4Plus operation mode.
operation mode (C4P). In case of wrong code,
the display will show the message "E–5" during
10 seconds and will automatically exit from the
programming mode.
The display will show the following messages:
C–1 (relay 1), C–2 (relay 2), C–3 (relay 3) or
C–4 (relay 4).
from the last operation.
30
31
L
ock release installation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole . In case of wood door,
use a Ø3mm. drill .
IMPORTANT: a varistor and a diode are supplied with this proximity reader.
a.c. lock release
LOCK RELEASE INSTALLATION
In case to connect an a.c. lock release, place the varistor
on the lock release terminals directly.
In case to connect an d.c. lock release, place the diode
on the lock release terminals directly. Special attention
on polarity is required.
d.c. lock release
3,5 x 25
DIN-7972
M 4 x 8
DIN-963
-
+
1N4007

Publicidad

Tabla de contenido
loading

Tabla de contenido