Fault
Drawer hits the end
stop with too much
force when opening
Drawer does not open
wide enough
When contacting an authorised expert, please have the following information ready:
•
Part number on the power supply unit, see ill. 3.
•
Serial number and part number on the drive, see ill. 4.
•
Conditions in which the problem occurred
»
Make sure that the range of required tasks can be narrowed down, and the required spare part ordered,
using the table.
Ill. 3:
Part Number power supply
unit
Cause
Carcass is not aligned horizontally
The opening force switch is set incorrectly
Carcass is not aligned horizontally
The opening force switch is set incorrectly
The opening unit is defective
Ill. 4:
Serial Number and Part
Number of opening unit
Remedy
Align carcass
Set switch to the left – see chapter 6.0:
Adjusting the opening force
Align carcass
Set switch to the right – see chapter 5.0:
Replacement
Replace drive – see chapter 6.0:
Adjusting the opening force