Festo DGEA- YSR Serie Instrucciones De Utilizacion página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
DGEA-...-YSR
2
Method of operation and use
The DGEA-...-YSR has been designed for fastening shock absorbers on the canti-
lever axis type DGEA-... in the area of the stroke reserve.
It is not intended as a fixed stop in the positioning range of the cantilever axis.
3
Conditions of use
When fitting to cantilever axes which are already set:
Check whether a speed limitation or a mass modification to the DGEA-... is
S
necessary.
The use of the shock absorber causes an additional torque on the cantilever
arm.
The DGEA-... can only be operated reliably (see also the technical specifica-
tions for the shock absorber) if the maximum loading limits are not exceeded.
4
Fitting
1. Position the cantilever arm in a mechan-
ical end position (W).
2. Push the cantilever arm out of the end
position by the dimension Y.
DGEA-...
18
25
40
10
Dimension Y [mm]
Shock absorber stroke
+ 5.5 mm
Shock absorber stroke
+ 2 mm
Shock absorber stroke
+ 2 mm
(w)
y
Fig. 2
Festo DGEA-...-YSR 0106NH English
(w)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dgea-18- ysr serieDgea-25- ysr serieDgea-40- ysr serieDgea ysr serie

Tabla de contenido