Problem
Unit will not light.
Burner will not stay lit
when gas valve plunger
is released
Excessive flames coming
out of burner, not
glowing red. Flames
flashback / burn inside
the mixing tube.
© 2018 Pinnacle Climate Technologies, Inc.
WHILE BURNING OR WHILE CONNECTED

TROUBLESHOOTING GUIDE

Possible Cause(s)
1. Valve on propane cylinder
closed.
2. Propane cylinder empty.
3. Regulator not in
position.
4. Defective regulator
1. Tip switch activated or
defective.
2. Wire terminal connections
unplugged.
3. Defective thermocouple.
4. Defective MPU.
1. Air inlet holes blocked or
covered.
2. Burner screen damaged.
3. Gap between burner screen
and burner can.
NEVER LEAVE HEATER UNATTENDED
TO A FUEL SOURCE
1. Open cylinder valve by turning
COUNTERCLOCKWISE.
2. Refill cylinder.
(HI)
3. Turn regulator to
position.
4. Replace regulator assembly.
1. Place heater in upright position
or replace tip switch.
2. Check wiring connections.
3. Replace thermocouple.
4. Replace MPU.
1. Clear any obstructions
2. Replace Burner screen.
3. Replace or repair burner head
assembly.
Propane Tank Top Heater User's Manual
13