Gas Supply Requirements - Wolf ICBGC152T/S Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SPECIFICATIONS
Gas Supply
Installation must conform with local codes and ordinances.
Locate the gas supply as shown in the illustrations on
page 4.
The cooktop is equipped for use with natural or liquid pro-
pane (LP) gas. The product rating plate has information on
the type of gas that should be used. For rating plate loca-
tion, refer to the illustration below. If this information does
not agree with the type of gas available, check with the local
gas supplier.
Prior to installation, ensure that the local distribution condi-
tions (nature of the gas and gas pressure) and the adjust-
ment of the appliance are compatible. The adjustment
conditions for this appliance are stated on the label (or
rating plate). The data plate can be found on the underside
of the cooktop.
This appliance is not connected to a combustion prod-
ucts evacuation device. It shall be installed and connected
in accordance with current installation regulations. Par-
ticular attention shall be given to the relevant requirements
regarding ventilation.

GAS SUPPLY REQUIREMENTS

NATURAL GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
LP GAS
Gas Supply Pressure
Min Line Pressure
Max Pressure to Regulator
RATING PLATE
Rating plate location.
WF Intl GCooktops IG MultiLang 824551A 10-13.indd 3
GAS RATING
TOTAL HEAT
GAS
MODEL
OUTPUT
UNITS
ICBGC152T/S
6.2
kW
ICBCG152T/S/LP
1594
g/h
ICBCG304T/S
14.2
kW
ICBCG304T/S/LP
3651
g/h
ICBCG304P/S
14.2
kW
ICBCG304P/S/LP
3651
g/h
ICBCG365T/S
16.9
kW
12.5 mb
17.5 mb
100 mb
ICBCG365T/S/LP
4345
g/h
25 mb
27.4 mb
ICBCG365P/S
16.9
kW
100 mb
ICBCG365P/S/LP
4345
g/h
APPLIANCE
TYPES AND
CATEGORY
PRESSURE (mbar)
COUNTRY OF DESTINATION
AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV, LT,
I2H
G20 at 20
NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
I2E
G20 at 20
DE, LU, PL
I2E+
G20 at 20/25
BE, FR
I3P
G31 at 37
FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV, LT,
I2H
G20 at 20
NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
I2E
G20 at 20
DE, LU, PL
I2E+
G20 at 20/25
BE, FR
I3P
G31 at 37
FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV, LT,
I2H
G20 at 20
NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
I2E
G20 at 20
DE, LU, PL
I2E+
G20 at 20/25
BE, FR
I3P
G31 at 37
FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV, LT,
I2H
G20 at 20
NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
I2E
G20 at 20
DE, LU, PL
I2E+
G20 at 20/25
BE, FR
I3P
G31 at 37
FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV, LT,
I2H
G20 at 20
NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
I2E
G20 at 20
DE, LU, PL
I2E+
G20 at 20/25
BE, FR
I3P
G31 at 37
FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
The cooktop must be connected to a regulated gas supply.
The supply line must be equipped with an approved external
gas shut-off valve located near the cooktop in an accessible
location. Do not block access to the shut-off valve. Refer to
the illustration below.
A gas supply line of 19 mm rigid pipe must be provided to
the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units
1
/
" NPT (or ISO 7/1-14)
2
male inlet to the gas supply line. Pipe joint compounds, suit-
able for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 100
mbar. The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the system at test pressures
equal to or less than 100 mbar.
Wolf natural gas cooktops will function up to 3124 m in
altitude without adjustment and LP gas cooktops will func-
tion up to 2621 m. If the installation exceeds these eleva-
tions, contact your authorized Wolf dealer for a high altitude
conversion kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.
|
wolfappliance.com
2/19/14 12:08 PM
3

Publicidad

Tabla de contenido
loading

Tabla de contenido