Parameter Menus
Use the arrow buttons to access the following parameter menus.
Group and Channel
A group is a set of compatible frequencies. A single
frequency within a group is a channel.
G:
Change the group
Ch:
Change the channel
F1: and F2: Frequency
Use the set and arrow keys to change the frequency
in 25 KHz increments.
Disable F2
When in frequency diversity mode, the second
frequency can be disabled from the F2: frequency
menu or the F2: group and channel menu.
F2: ON
Enable F2
F2: OFF
Disable F2
Gain
Sets the input sensitivity level (gain). Gain range is
-10 to +32 dB in 1 dB steps.
RF Mute
Disables the RF carrier signal, which mutes trans-
mission of audio.
TX On:
RF signal enabled
TX Off:
RF signal disabled
Troubleshooting
No ShowLink Alert
This alert appears when frequency is edited on a linked transmitter that is beyond
the range of an active ShowLink access point. Choose OK to unlink the transmitter
and complete the frequency change, or Cancel to return to the home screen.
Input Overload
The Input Overload message indicates an excessive signal level at the transmit-
ter input. To prevent overload, reduce the gain setting.

Firmware Updates

Firmware is embedded software used to control features and the user interface. Periodically, new versions of firmware are available for download from www.shure.com/wwb
to incorporate additional features and enhancements. New versions of the firmware can be downloaded to AXT400 Receiver using the Firmware Update Manager tool avail-
able in WWB6 software and installed on the transmitter using the infrared ports on the transmitter and receiver.
To access the AXT400 receiver firmware update menu: Tx > IR Presets > FW Update
Firmware
Displays the installed firmware version.
Device ID
Identifies the transmitter on a linked receiver or in
WWB software.
• ID length can be up to 8 characters
• Use arrow buttons to scroll through characters
• Use set button to save and move to the next
character
AA Type
This setting ensures accurate battery metering
when using the optional AA battery carrier. Set the
battery type to Alkaline, NiMH, or Lithium.
Note: Menu not displayed unless an AA battery car-
rier is installed.
ShowLink Test
Activates the ShowLink test 5-bar display.
Measures the remote control range of a ShowLink
Access Point.
• 5 bars indicate the center of the coverage
area
• 1 bar indicates the outer boundary of the
coverage area
• If bars are not displayed, ShowLink control is
not available
Deeply Discharged Batteries
Deep discharge occurs when a battery is discharged to less than 3.0 volts. The
battery chargers have a recovery mode designed to restore charge to a deeply
discharged battery.
When the charger detects a deeply discharged battery, it automatically enters re-
covery mode which supplies reduced current to the battery for up to 30 minutes.
If recovery is successful, the charger will exit recovery mode and charge the bat-
tery to capacity. If the battery cannot be recharged, charging stops and the battery
must be replaced.
3
Unlink
Ends the Link relationship between transmitter and
receiver.
YES:
Ends the Link between transmitter and receiver.
NO:
Preserves the Link between transmitter and
receiver.
Note: When a transmitter is unlinked, the channel
name reverts to Unlinked.
RF PWR
Sets RF power level. Access this menu by pressing
and holding the set button and then pressing the ▼
button.
Use lower power settings to conserve battery life
and to prevent RF overload at the receiver.
Note: A password is required in some regions.
PCB Serial Number
Displays the serial number of the printed circuit
board (PCB) installed in the unit.
1. Enter the RF PWR menu by pressing and holding
the set button, and then pressing the ▼ button.
2. Press the ▲ button to access the serial number.
3. Momentarily press the power button to return to
the home menu screen.