COMMISSIONING
1 - Once the hydraulic and electrical connections have been
made, check that the connections are tight by allowing
water to flow through each entry point used. Ensure that
each pump is working properly. .
2 -
WARNING!
Do not force the motors to start
(by pressing the push buttons on the casing) before
water is let into the pumps. Forced dry functioning
damage the grinding system.
1 1
USE
1- S A N I C U B I C
®
is designed to evacuate all domestic
wastewater. Any other application of the apparatus may
render the guarantee void. Never use it for paper towels,
condoms or sanitary items, oils, solvents...
2-
WARNING: In the event of a power failure, turn off
all water flowing into appliances connected
to S A N I C U B I C
®
.
1 2
CLEANING
To remove anything that cannot be evacuated from the
tank:
- Disconnect the appliance,
- Unscrew the 100mm plug,
- Retrieve the items using a pair of pincers.
1 3
ALARM
ELECTRICAL INSTA L L ATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
The alarm system depends on the user's choice (lamp,
buzzer) and the required distance (200-V contact on the
electronic card).
CONNECTING THE ALARM
Two 6.35 connections are available on the electronic card
for creating an alarm circuit (these connections have an
electric current flow of 220V, 5A). To reach the connections,
cut off the power then remove the large cover followed by
the small cover. When the card is half-extracted, the two
connections will appear. Use a round electrical cable 2 x
0.75 mm2, which must pass through the empty stuffing box
before being connected to the alarm system.
WARNING:
This alarm will not operate if there is a
power-cut.
In no circumstances should the mounting of the two
pressure tubes and the two pressure readers on the card
(the level reader and the alarm reader) be inverted during
maintenance or checking (see diagram 15 a).
The following mounting must be checked every time:
1 - Normal pressure tube B : Level pressure reader,
Black flex.
2 - Short pressure tube A : Alarm pressure reader, Clear
f l e x .
Inversion will set off the alarm each time the equipment
is operated.
N.B. The alarm pressure reader is marked with the letter A o n
the electronic card.
1 4
FIRST LEVEL TROUBLESHOOTING
ELECTRICAL INSTA L L ATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
PROBLEMS
• Neither of the motors starts
1. The appliance is not switched on
2. The cable is defective
• The alarm sounds
1. Pumps blocked
2. Pumps jammed
For all other intervention, disconnect the electrical current.
SECONDARY TROUBLESHOOTING
PROBLEM ENCOUNTEREDE
• Motor does not start
1. Pressure reader tubes kinked or
out of position
2. Electronic card defective
• Pumps working constantly
1. A level pressure pipe is blocked
2. Ve rtical discharge too high
3. Electronic card defective
• Alarm sounding
1. Pumps blocked
2. Pumps jammed
3.Grinding systems blocked
4. Electrical problems with motor
5. Too much water flowing
through
6. Electronic card defective
• Intermittent start-up of pumps
1. The non-return valves broken or
leaking
2. Electronic card defective
1 5
REMOVAL
ELECTRICAL INSTA L L ATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
REMOVING A MOTOR
15a
1
SWITCH THE APPLIANCE OFF (the yellow indicator
light must be out).
2
Unscrew the three fixing screws on the housing and remove.
3
Empty the tank.
To access the anti-backflow valves:
4
Unscrew the clips and then remove both sides of the
hose Y (36/37).
5
Clean or replace the valves (45/46).
To access the cutter
6
Unscrew the six screws (66) torx T20.
7
Turn the motor anti-clockwise (warning: the motor may
be hot) and lift it out.
8
Remove the three screws that hold the cutter assembly
to the motor. Clean or change the entire cutter.
When replacing, follow the guides (with the holes in the
plate well free).
REPLACING A MOTOR
15b
Before replacing the motor in the body of the pump,
1
Align the impeller (61) with the reference mark for the
lower case of the motor (43).
2
Align the drive coupling (64) with the reference mark on
the holder (47).
3
Locate the motor into the adaptor plate, ensure it is firmly
home and turn it clockwise until the reference marks line up.
4
Screw in the six screws into the adaptor plate.
Check that the motor can turn freely using a screwdriver
5
into the top of the motor shaft.
1 5
GUARANTEE
S A N I C U B I C
®
is guaranteed for two years for parts and
labour provided it is both installed and used in accordance
with the current instruction notice.
PROBABLE CAUSE
REMEDY
1. Check the electrical installation.
1. Operate the pump which is
displaying the alarm light, using
the forced operation button
(pressing repeatedly).
PROBABLE CAUSE
REMEDY
1. Remove or replace the tubes.
2. Consult an SFA - a p p roved
b reakdown technician.
1. Extract the level pressure pipe
unblock it.
2. Examine the appliance.
3. Consult an SFA - a p p roved
b reakdown technician.
1. IAdjust the pump which is
displaying the alarm:
• Using a screwdriver, turn the
motor shaft by accessing it
through the hood.
• Remove the pump and
unblock it.
If the pump revolves but does not
pump, consult an SFA-approved
breakdown technician.
6. Consult an SFA - a p p roved
b reakdown technician.
1. Clean or change the valves.
2. Consult an SFA - a p p roved
b reakdown technician.